Contichrom® TWIN 300 LPLC - Capture
The Contichrom® TWIN 300 LPLC – Capture is a sanitary chromatography system for continuous capture of biologics from pilot to large-scale GMP manufacturing. Featuring patented CaptureSMB® technology with AutomAb® dynamic control, the system maximizes resin binding capacity to deliver up to 3× faster processing and 50% less Protein A resin and buffer consumption compared to batch chromatography. Purpose-built for monoclonal antibodies, viral vectors (AAV), and recombinant proteins, the system features a fully sanitary, CIP-ready flow path in SS 316L or Hastelloy with a 7.5-bar maximum operating pressure. The TWIN 300 has flow rates from 0.03 – 3.33 L/min.
- Contichrom® TWIN 300 LPLC - Capture
- Contichrom® TWIN 500 LPLC - Capture
- Contichrom® TWIN 1000 LPLC - Capture
- Contichrom® TWIN 2000 LPLC - Capture
Overview
GMP-Ready Continuous Capture for Biopharmaceutical Manufacturing
The Contichrom® TWIN LPLC – Capture is a sanitary chromatography system for continuous capture of biologics from pilot to large-scale GMP manufacturing.
- Twin-column continuous capture (CaptureSMB® with AutomAb®)
- Up to 3× faster processing, 50% less resin and buffer vs. batch
- Sanitary design with CIP capability for biopharmaceutical production
- SS 316L or Hastelloy flow paths, 7.5 bar maximum operating pressure
- 21 CFR Part 11 compliant software with full audit trail
One System, Multiple Processes
Batch AND continuous capture on a single sanitary skid:
| Mode | Technology |
|---|---|
| Batch | Single-column isocratic and gradient |
| 2D Integrated Batch | Two-step purification with in-line dilution (BID) |
| Continuous Capture | CaptureSMB® with AutomAb® |
- Switch seamlessly between batch and CaptureSMB® modes
- Buffer in-line dilution (BID) option for on-board pH adjustment
- Eliminates duplicate equipment — saves space and capital
Patented CaptureSMB Technology
Twin-column continuous capture maximizing resin binding capacity:
| Metric | Value |
|---|---|
| Speed | Up to 3× faster than batch |
| Resin & buffer | Up to 50% reduction |
| Productivity | 2–4× vs. single-column batch |
- Two columns alternate loading and elution — continuous output
- Columns in series so the second captures breakthrough from the first
- Near-complete resin utilization eliminates re-chromatography
AutomAb® - Dynamic Process Control
AutomAb® monitors UV breakthrough in real time and adjusts column switching automatically:
- Detects product breakthrough and triggers switching at the optimal point
- Compensates for feed variability, column aging, and resin degradation
- Delivers consistent capture efficiency without operator intervention
- Enables robust, continuous 24/7 manufacturing
- Steady state reached after only one cycle with <1% variability
Comprehensive Application Range
Production-scale capture for biopharmaceuticals:
| Application | CaptureSMB® | Integrated Batch |
|---|---|---|
| mAbs & Antibody Variants | ✓ | ✓ |
| Viral Vectors (AAV) | ✓ | ✓ |
| Antibody-drug Conjugates | ✓ | ✓ |
| Recombinant Proteins | ✓ | ✓ |
- All processes run on the same sanitary hardware
- AutomAb® dynamic control across continuous operations
Scalable from Lab to Production
Part of the Contichrom® platform with established transfer protocols:
| System | Flow Rate | Column ID |
|---|---|---|
| CUBE 30/100 | 0.1–100 mL/min | 0.5–5 cm |
| TWIN LPLC 300 | 0.03 – 3.33 L/min | 10–20 cm |
| TWIN LPLC 500 | 0.08 – 8.33 L/min | 20–45 cm |
| TWIN LPLC 1000 | 0.15 – 18.9 L/min | 30–60 cm |
| TWIN LPLC 2000 | 0.5 – 36 L/min | 60–100 cm |
- Scale-up from CUBE at over 100× verified and published
- Same CaptureSMB® and AutomAb® control at every scale
Sanitary Design for Bioprocessing
Purpose-built for biopharmaceutical manufacturing environments:
- Fully sanitary flow path with drainable design and CIP compatibility
- ASME-BPE compliant stainless steel welds on all product contact surfaces
- SS 316L or Hastelloy flow path materials
- SF5 spec product contact tubing (≤ 20 Ra EP)
- Designed for NaOH 1M CIP and compatible with single-use aseptic interfaces
- Maximum operating pressure of 7.5 bar — optimal for affinity and LP resins
Designed for GMP Compliance
Built to meet stringent biopharmaceutical manufacturing requirements:
- Developed under the GAMP 5 framework
- 21 CFR Part 11 compliant software with audit trail
- Comprehensive Turnover Package (TOP) with ASME-BPE compliant welds
- USP Class VI materials and FDA-approved seals
- UL-approved panels, CE marking including PED compliance
TOP includes: MTRs, pressure test reports, passivation reports, weld documentation, as-built drawings.
Production-Grade Hardware
A complete skid-mounted system with mobile frame:
- 2× Pumps (base) — LEWA ecodos triplex with rupture detection
- 3rd Pump (BID option) — Buffer in-line dilution
- Dual UV Detectors — 4-Channel Adjustable wavelength (200-600 nm), 0.5 mm path length
- 2× Coriolis flow meters + 8× pressure transmitters
- pH, conductivity & temperature — Post-column standard
- Air sensors — Pre-pump and pre-column
- Pneumatic valves — Sanitary design, fast-acting at low pressure
- 24″ HMI — Industrial touchscreen with FactoryTalk View SE
CIP-Ready Design
The Contichrom® TWIN LPLC – Capture is designed for cleaning-in-place:
- Dedicated CIP inlet and outlet manifolds integrated into the valve network
- Fully drainable flow path design minimizes carryover between campaigns
- Compatible with NaOH 1M CIP protocols
- Optional single-use aseptic interface for minimally classified suites
- Reduces turnaround time and supports multi-product facility operation
How it works
Sanitary Hardware for GMP Biopharmaceutical Capture Chromatography
The Contichrom TWIN LPLC – Capture is a complete sanitary skid-mounted unit for GMP manufacturing:
- Mobile frame with levelers and non-marking caster wheels
- 316L stainless steel frame with mechanically polished welds
- Sanitary flow path designed for drainability and CIP
- Two column positions for CaptureSMB and single-column batch
- Operating temperature: 4–25 °C ambient, 4–40 °C process
LEWA Ecodos Triplex Pumps
Industry-leading LEWA ecodos triplex pumps for precision and reliability:
| Pump | Role |
|---|---|
| Pump A | Feed delivery / Load buffer |
| Pump B | Elution / Wash / Equilibration |
| Pump C (optional) | Buffer in-line dilution (BID) |
- Triplex configuration for nearly pulse-free flow
- Sandwich diaphragm with rupture detection alarm
- Automatic stroke adjustment for optimal performance
- PTFE diaphragms — USP Class VI certified, FDA approved
- Base system includes 2 pumps; 3rd pump available with BID option
Pneumatic Valve Network
Sanitary pneumatic valves — fast-acting at low pressure:
- Inlet Selection Valves — Multiple ports per pump for automated buffer/feed switching
- Column Switching Valves — For CaptureSMB interconnected and parallel configurations
- Fraction Outlet Valves — Product and waste routing with drain connection
- CIP Manifolds — Dedicated inlet and outlet for cleaning-in-place
- Materials: 316L SS body, PTFE/EPDM diaphragm, SF5 spec product contact (≤ 20 Ra EP)
- Sanitary design
Dual Wavelength UV Detectors
Two post-column UV sensors for real-time monitoring and AutomAb® control:
| Parameter | Specification |
|---|---|
| Type | 4-channel, multi-wavelength DAD, 200–600 nm |
| Path length | 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
- Provides the UV breakthrough signals that enables AutomAb® dynamic process control
- Critical for consistent CaptureSMB® capture efficiency
In-Line Process Sensors
Comprehensive real-time monitoring:
| Sensor | Quantity | Specification |
|---|---|---|
| Coriolis Flow Meters | 2 | Flow monitoring and control |
| Pressure Transmitters | 8 | 0–13.8 bar, ±1% FS |
| pH | Post-column (x2) | 0–13 pH, ±0.15 unit |
| Conductivity | Post-column (x2) | 0–200 mS/cm, ±1% of measured value |
| Temperature | Per column | 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump + pre-column | Ultrasonic detection |
Column Management
Flexible column configurations for production scale:
- 2 column positions for CaptureSMB® twin-column operation
- Column ID range: 10–100 cm (depending on model)
- Low-pressure operation Max 7.5 bar — optimized for affinity resins
- Sanitary tri-clamp connections for column attachment
- Single-column batch mode available
Human-Machine Interface (HMI)
System control via industrial PC running FactoryTalk View SE:
| Component | Specification |
|---|---|
| Touchscreen | 24″ industrial HMI, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
- Real-time process visualization, recipe management, batch reporting
GMP-Grade Flow Path
Every product-contact surface selected for biopharmaceutical compatibility:
| Component | Materials |
|---|---|
| Product Contact Tubing | 316L SS or Hastelloy, ≤ 20 Ra EP (SF5 spec) |
| Non-Product Contact Tubing | 316L SS, ≤ 20 Ra MP (SF1 spec) |
| Process Valves | 316L SS body, PTFE/EPDM diaphragm |
| Pump Diaphragms | PTFE (USP Class VI, FDA approved) |
- ASME-BPE compliant welds, drainable design, CIP-compatible
- Surface roughness < 0.8 µm Ra on wetted metallic parts
PLC-Based Control System
Industrial automation platform:
| Component | Specification |
|---|---|
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
Optional Hardware
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Process Capabilities
Continuous Capture for Biopharmaceutical Production
The Contichrom TWIN LPLC – Capture is optimized for twin-column continuous capture:
- CaptureSMB® with AutomAb® — Continuous capture
- 2D Integrated Batch — Two-step purification with in-line dilution (BID option)
- Batch — Single-column isocratic and gradient operation
- All accessible from a single sanitary GMP-ready platform
CaptureSMB® with AutomAb® — Continuous Capture
Twin-column continuous capture maximizing resin binding capacity:
- Two identical columns alternate between loading and elution
- Columns in series — second column captures breakthrough from the first
- AutomAb® detects UV breakthrough and triggers column switching
- Near-complete utilization of resin binding capacity
- Continuous feed processing eliminates batch size limitations
- Steady state after one cycle with <1% variability
Target: Affinity capture steps (Protein A, mixed-mode) Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
CaptureSMB® — Performance Gains
| Metric | Result |
|---|---|
| Processing speed | Up to 3× faster than batch |
| Protein A resin consumption | Up to 50% reduction |
| Buffer consumption | Up to 50% reduction |
| Productivity | 2–4× higher vs. single-column batch |
| Intermediate storage | Reduced — continuous output eliminates hold steps |
| Process control | AutomAb® enables continuous 24/7 operation |
| Scale-up variability | <1% — steady state after one cycle |
One column loads while the other elutes — continuous output, maximum resin utilization, consistent quality.
Integrated Batch — Two-Step Purification
Couple two chromatography steps without intermediate handling:
- Parallel or in-series column configurations
- Two chromatography modes run consecutively (e.g., IEX then HIC)
- On-board buffer in-line dilution (BID option) for pH adjustment
- Eliminates intermediate hold tanks and manual handling
- Reduces process time, QC burden, and facility footprint
Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
Batch Chromatography
Single-column batch purification:
| Mode | Applications |
|---|---|
| Isocratic | Affinity capture, SEC, desalting |
| Gradient | IEX, HIC, mixed-mode polishing |
- Linear gradient from 5% to 95% in batch mode
- Multiple fraction collection outlets
- Full UV/flow/pressure/pH/conductivity monitoring
Buffer In-line Dilution (BID)
On-board dilution of buffer concentrates and CIP solutions:
- Third pump (Pump C) delivers dilution buffer at controlled ratio
- Static mixer ensures homogeneous blending
- Enables pH adjustment between capture and polish steps
- Supports sequential processing for pool-less multi-step chromatography
Requires: BID option (Pump C, inlet valves, static mixer, sensors)
Regulatory Compliance & Documentation
Certifications
- UL-approved electrical panels
- CE marking available including PED compliance
- Developed under GAMP 5 framework
- Complies with FDA 21 CFR Part 11 regulations
Standards & Directives
- ASME-BPE for all stainless steel product contact welds
- FDA-approved USP Class VI materials and seals
- UL-approved electrical panels
- CE marking with PED compliance
Materials & Documentation
- All wetted materials selected for biopharmaceutical compatibility and chemical resistance
- Full traceability with MTRs and certificates of compliance
- Product contact surface roughness: < 0.8 µm Ra (SF5 spec: ≤ 20 Ra EP)
- Turnover Package (TOP) with comprehensive QA/QC documentation
TOP includes: MTRs, certificates of compliance, pressure test reports, passivation reports, weld documentation (logs, inspection reports, procedures, coupon logs, isometrics), slope verification, operation and maintenance manuals, as-built drawings (PDF and native CAD/Solidworks).
Specifications
System Models
| Parameter | TWIN 300 | TWIN 500 | TWIN 1000 | TWIN 2000 |
|---|---|---|---|---|
| Flow Rate | 0.03 – 3.33 L/min | 0.08 – 8.33 L/min | 0.15 – 18.9 L/min | 0.5 – 36 L/min |
| Column ID | 10–20 cm | 20–45 cm | 30–60 cm | 60–100 cm |
| Max Operating Pressure | 7.5 bar | 7.5 bar | 7.5 bar | 7.5 bar |
| Best For | Pilot / clinical | Mid-scale GMP | Large-scale GMP | Maximum capacity |
General Specifications
| Specification | Value |
|---|---|
| Max Operating Pressure | 7.5 bar (0.75 MPa / 109 psi) |
| Operating Temperature | 4–25 °C ambient; 4–40 °C process |
| Design | Sanitary, CIP-compatible (NaOH 1M) |
| Wetted Materials | SS 316L or Hastelloy, PTFE, EPDM (USP Class VI) |
| Surface Finish | < 0.8 µm Ra (product contact), SF5 spec: ≤ 20 Ra EP |
| Control System | Rockwell CompactLogix PLC |
| Processes | Batch, Integrated Batch, CaptureSMB® |
Physical Specifications
| Model | Length | Width | Height | Approx. Weight |
|---|---|---|---|---|
| TWIN 300 | 218 cm | 127 cm | 203 cm | 2494 kg |
| TWIN 500 | 299 cm | 165 cm | 198 cm | 3055 kg |
| TWIN 1000 (Pump) | 360 cm | 140 cm | 230 cm | 4455 kg |
| TWIN 1000 (Process) | 140 cm | 90 cm | 200 cm | 1364 kg |
| TWIN 2000 (Pump) | 381 cm | 152 cm | 230 cm | 4763 kg |
| TWIN 2000 (Process) | 147 cm | 101 cm | 200 cm | 1543 kg |
Pumps (LEWA ecodos)
| Configuration | 2× triplex diaphragm pumps (3× with BID option) |
| Diaphragm | Sandwich PTFE with rupture detection |
| Materials | USP Class VI certified, FDA approved |
| Features | Automatic stroke adjustment, nearly pulse-free flow |
Detectors & Sensors
| UV Detection | 4-channel, multi-wavelength DAD, 200–600 nm, 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
| Flow Meters (×2) | Coriolis |
| Pressure (×8) | Transmitters throughout flow path, 0–13.8 bar, ±1% FS |
| pH | On waste and collection outlets, 0–13, ±0.15 unit |
| Conductivity | On waste and collection outlets, 0–200 mS/cm, ±1% of measured value |
| Temperature | Post-column, 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump and pre-column (ultrasonic) |
Valves & Flow Path
| Valve Actuation | Pneumatic diaphragm valves |
| Valve Materials | 316L SS body, PTFE/EPDM diaphragm |
| Product Contact | SF5 spec: ≤ 20 Ra EP |
| Non-Product Contact | SF1 spec: ≤ 20 Ra MP |
| Column Connections | Sanitary tri-clamp |
| CIP | Dedicated inlet and outlet manifolds |
Software & Automation
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB® with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
| Data Integrity | 21 CFR Part 11, audit trail, electronic signatures |
User Interface
| HMI | 24″ industrial touchscreen, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
Optional Modules
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Technologies
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Applications
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
Resources
- All Media Types
- Peer-Reviewed Publications
Scale-Up of Twin-Column Periodic Counter-Current Chromatography for MAb Purification, BioProcess Int.
CaptureSMB scale-up from laboratory to manufacturing scale establishes engineering principles for continuous capture process transfer.
Service & Support
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
FAQ
A complete Contichrom® TWIN LPLC – Capture system includes:
- Complete sanitary skid assembly with mobile frame (levelers and casters)
- 2× LEWA ecodos triplex pumps with sandwich diaphragms and rupture detection
- Full inlet and outlet pneumatic valve network (sanitary design)
- Dual wavelength UV detectors (280 nm, 303 nm)
- Post-column pH and conductivity sensors
- 2× Coriolis flow meters + 8× pressure transmitters
- Pre-pump and pre-column air sensors
- CIP inlet and outlet manifolds
- 24″ HMI with industrial PC and control software preloaded
- Rockwell CompactLogix PLC control system
- Comprehensive TOP documentation package
- Factory Acceptance Testing (FAT) — up to 5 days
- One week on-site startup support and training
Customer provides: Columns, filter elements, chromatography resin, external piping, utilities connections.
| Feature | TWIN HPLC | TWIN LPLC Capture | TWIN LPLC Polishing |
|---|---|---|---|
| Design | Industrial (non-sanitary) | Sanitary | Sanitary |
| Pressure | 80 bar | 7.5 bar (20 bar opt.) | 7.5 bar (20 bar opt.) |
| Core Process | MCSGP (polishing) | CaptureSMB® (capture) | MCSGP (polishing) |
| HP Valves | YMC fast-acting | Standard pneumatic | Standard pneumatic |
| Pumps | 4× LEWA ecoflow | 2× (3×) LEWA ecodos | 4× LEWA ecodos |
| Molecules | Synthetic peptides, oligos | Biologics (mAbs, AAV, ADCs) | Biologics (mAbs, AAV, ADCs) |
The TWIN LPLC – Capture is the right choice for affinity capture of biopharmaceuticals where sanitary design and CIP capability are required.
| Model | Column ID | Flow Rate | Best For |
|---|---|---|---|
| TWIN 300 | 10–20 cm | 0.03 – 3.33 L/min | Pilot production, clinical manufacturing |
| TWIN 500 | 20–45 cm | 0.08 – 8.33 L/min | Mid-scale commercial production |
| TWIN 1000 | 30–60 cm | 0.15 – 18.9 L/min | Large-scale commercial production |
| TWIN 2000 | 60–100 cm | 0.5 – 36 L/min | Maximum capacity production |
Contact YMC to discuss your throughput requirements and optimal system selection.
- Floor space: Dimensions vary by model (contact YMC for GA drawings)
- Power: Model-dependent (contact YMC for specifications)
- Utilities: Process air, water, compressed air, drain, network connection
- Ambient temperature: 4–25 °C
- Process temperature: 4–40 °C
Note: System must be uncrated, leveled, and connected to utilities before YMC on-site work begins.
- Methods developed on Contichrom CUBE transfer directly to the TWIN LPLC
- Same CaptureSMB® principles and AutomAb® control at both scales
- Scale-up at over 100× verified and published
- Steady state after one cycle with <1% variability
- YMC ChromaCon provides process transfer support
- FAT — Up to 5 days at YMC facility
- On-site startup — One week including commissioning and system walkdown
- Training — 1 full day or 2 half-days covering operation and maintenance
- Remote support — HMS Ewon remote access for troubleshooting and training
- Warranty: 12 months from installation or 18 months from shipment (whichever first)
- Global service: YMC operations worldwide, LEWA support in 80 countries
- Remote access: Built-in capability for automation troubleshooting
- Components: Non-proprietary with global distribution for local acquisition
- Maintenance: No special tools required for standard maintenance
Yes — customization options include:
- Buffer in-line dilution (BID) with additional pump
- Additional inlet valves (up to 6 on Pump A, B, or C)
- Additional outlet/fraction valves (up to 5 fraction + 1 waste)
- Pre-column analytics (pH and conductivity)
- Single or dual filter housings
- Bubble traps
- CIP manifolds for aseptic single-use bag connection
Contact YMC ChromaCon for custom configuration pricing.
Overview
GMP-Ready Continuous Capture for Biopharmaceutical Manufacturing
The Contichrom® TWIN LPLC – Capture is a sanitary chromatography system for continuous capture of biologics from pilot to large-scale GMP manufacturing.
- Twin-column continuous capture (CaptureSMB® with AutomAb®)
- Up to 3× faster processing, 50% less resin and buffer vs. batch
- Sanitary design with CIP capability for biopharmaceutical production
- SS 316L or Hastelloy flow paths, 7.5 bar maximum operating pressure
- 21 CFR Part 11 compliant software with full audit trail
One System, Multiple Processes
Batch AND continuous capture on a single sanitary skid:
| Mode | Technology |
|---|---|
| Batch | Single-column isocratic and gradient |
| 2D Integrated Batch | Two-step purification with in-line dilution (BID) |
| Continuous Capture | CaptureSMB® with AutomAb® |
- Switch seamlessly between batch and CaptureSMB® modes
- Buffer in-line dilution (BID) option for on-board pH adjustment
- Eliminates duplicate equipment — saves space and capital
Patented CaptureSMB Technology
Twin-column continuous capture maximizing resin binding capacity:
| Metric | Value |
|---|---|
| Speed | Up to 3× faster than batch |
| Resin & buffer | Up to 50% reduction |
| Productivity | 2–4× vs. single-column batch |
- Two columns alternate loading and elution — continuous output
- Columns in series so the second captures breakthrough from the first
- Near-complete resin utilization eliminates re-chromatography
AutomAb® - Dynamic Process Control
AutomAb® monitors UV breakthrough in real time and adjusts column switching automatically:
- Detects product breakthrough and triggers switching at the optimal point
- Compensates for feed variability, column aging, and resin degradation
- Delivers consistent capture efficiency without operator intervention
- Enables robust, continuous 24/7 manufacturing
- Steady state reached after only one cycle with <1% variability
Comprehensive Application Range
Production-scale capture for biopharmaceuticals:
| Application | CaptureSMB® | Integrated Batch |
|---|---|---|
| mAbs & Antibody Variants | ✓ | ✓ |
| Viral Vectors (AAV) | ✓ | ✓ |
| Antibody-drug Conjugates | ✓ | ✓ |
| Recombinant Proteins | ✓ | ✓ |
- All processes run on the same sanitary hardware
- AutomAb® dynamic control across continuous operations
Scalable from Lab to Production
Part of the Contichrom® platform with established transfer protocols:
| System | Flow Rate | Column ID |
|---|---|---|
| CUBE 30/100 | 0.1–100 mL/min | 0.5–5 cm |
| TWIN LPLC 300 | 0.03 – 3.33 L/min | 10–20 cm |
| TWIN LPLC 500 | 0.08 – 8.33 L/min | 20–45 cm |
| TWIN LPLC 1000 | 0.15 – 18.9 L/min | 30–60 cm |
| TWIN LPLC 2000 | 0.5 – 36 L/min | 60–100 cm |
- Scale-up from CUBE at over 100× verified and published
- Same CaptureSMB® and AutomAb® control at every scale
Sanitary Design for Bioprocessing
Purpose-built for biopharmaceutical manufacturing environments:
- Fully sanitary flow path with drainable design and CIP compatibility
- ASME-BPE compliant stainless steel welds on all product contact surfaces
- SS 316L or Hastelloy flow path materials
- SF5 spec product contact tubing (≤ 20 Ra EP)
- Designed for NaOH 1M CIP and compatible with single-use aseptic interfaces
- Maximum operating pressure of 7.5 bar — optimal for affinity and LP resins
Designed for GMP Compliance
Built to meet stringent biopharmaceutical manufacturing requirements:
- Developed under the GAMP 5 framework
- 21 CFR Part 11 compliant software with audit trail
- Comprehensive Turnover Package (TOP) with ASME-BPE compliant welds
- USP Class VI materials and FDA-approved seals
- UL-approved panels, CE marking including PED compliance
TOP includes: MTRs, pressure test reports, passivation reports, weld documentation, as-built drawings.
Production-Grade Hardware
A complete skid-mounted system with mobile frame:
- 2× Pumps (base) — LEWA ecodos triplex with rupture detection
- 3rd Pump (BID option) — Buffer in-line dilution
- Dual UV Detectors — 4-Channel Adjustable wavelength (200-600 nm), 0.5 mm path length
- 2× Coriolis flow meters + 8× pressure transmitters
- pH, conductivity & temperature — Post-column standard
- Air sensors — Pre-pump and pre-column
- Pneumatic valves — Sanitary design, fast-acting at low pressure
- 24″ HMI — Industrial touchscreen with FactoryTalk View SE
CIP-Ready Design
The Contichrom® TWIN LPLC – Capture is designed for cleaning-in-place:
- Dedicated CIP inlet and outlet manifolds integrated into the valve network
- Fully drainable flow path design minimizes carryover between campaigns
- Compatible with NaOH 1M CIP protocols
- Optional single-use aseptic interface for minimally classified suites
- Reduces turnaround time and supports multi-product facility operation
How it works
Sanitary Hardware for GMP Biopharmaceutical Capture Chromatography
The Contichrom TWIN LPLC – Capture is a complete sanitary skid-mounted unit for GMP manufacturing:
- Mobile frame with levelers and non-marking caster wheels
- 316L stainless steel frame with mechanically polished welds
- Sanitary flow path designed for drainability and CIP
- Two column positions for CaptureSMB and single-column batch
- Operating temperature: 4–25 °C ambient, 4–40 °C process
LEWA Ecodos Triplex Pumps
Industry-leading LEWA ecodos triplex pumps for precision and reliability:
| Pump | Role |
|---|---|
| Pump A | Feed delivery / Load buffer |
| Pump B | Elution / Wash / Equilibration |
| Pump C (optional) | Buffer in-line dilution (BID) |
- Triplex configuration for nearly pulse-free flow
- Sandwich diaphragm with rupture detection alarm
- Automatic stroke adjustment for optimal performance
- PTFE diaphragms — USP Class VI certified, FDA approved
- Base system includes 2 pumps; 3rd pump available with BID option
Pneumatic Valve Network
Sanitary pneumatic valves — fast-acting at low pressure:
- Inlet Selection Valves — Multiple ports per pump for automated buffer/feed switching
- Column Switching Valves — For CaptureSMB interconnected and parallel configurations
- Fraction Outlet Valves — Product and waste routing with drain connection
- CIP Manifolds — Dedicated inlet and outlet for cleaning-in-place
- Materials: 316L SS body, PTFE/EPDM diaphragm, SF5 spec product contact (≤ 20 Ra EP)
- Sanitary design
Dual Wavelength UV Detectors
Two post-column UV sensors for real-time monitoring and AutomAb® control:
| Parameter | Specification |
|---|---|
| Type | 4-channel, multi-wavelength DAD, 200–600 nm |
| Path length | 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
- Provides the UV breakthrough signals that enables AutomAb® dynamic process control
- Critical for consistent CaptureSMB® capture efficiency
In-Line Process Sensors
Comprehensive real-time monitoring:
| Sensor | Quantity | Specification |
|---|---|---|
| Coriolis Flow Meters | 2 | Flow monitoring and control |
| Pressure Transmitters | 8 | 0–13.8 bar, ±1% FS |
| pH | Post-column (x2) | 0–13 pH, ±0.15 unit |
| Conductivity | Post-column (x2) | 0–200 mS/cm, ±1% of measured value |
| Temperature | Per column | 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump + pre-column | Ultrasonic detection |
Column Management
Flexible column configurations for production scale:
- 2 column positions for CaptureSMB® twin-column operation
- Column ID range: 10–100 cm (depending on model)
- Low-pressure operation Max 7.5 bar — optimized for affinity resins
- Sanitary tri-clamp connections for column attachment
- Single-column batch mode available
Human-Machine Interface (HMI)
System control via industrial PC running FactoryTalk View SE:
| Component | Specification |
|---|---|
| Touchscreen | 24″ industrial HMI, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
- Real-time process visualization, recipe management, batch reporting
GMP-Grade Flow Path
Every product-contact surface selected for biopharmaceutical compatibility:
| Component | Materials |
|---|---|
| Product Contact Tubing | 316L SS or Hastelloy, ≤ 20 Ra EP (SF5 spec) |
| Non-Product Contact Tubing | 316L SS, ≤ 20 Ra MP (SF1 spec) |
| Process Valves | 316L SS body, PTFE/EPDM diaphragm |
| Pump Diaphragms | PTFE (USP Class VI, FDA approved) |
- ASME-BPE compliant welds, drainable design, CIP-compatible
- Surface roughness < 0.8 µm Ra on wetted metallic parts
PLC-Based Control System
Industrial automation platform:
| Component | Specification |
|---|---|
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
Optional Hardware
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Process Capabilities
Continuous Capture for Biopharmaceutical Production
The Contichrom TWIN LPLC – Capture is optimized for twin-column continuous capture:
- CaptureSMB® with AutomAb® — Continuous capture
- 2D Integrated Batch — Two-step purification with in-line dilution (BID option)
- Batch — Single-column isocratic and gradient operation
- All accessible from a single sanitary GMP-ready platform
CaptureSMB® with AutomAb® — Continuous Capture
Twin-column continuous capture maximizing resin binding capacity:
- Two identical columns alternate between loading and elution
- Columns in series — second column captures breakthrough from the first
- AutomAb® detects UV breakthrough and triggers column switching
- Near-complete utilization of resin binding capacity
- Continuous feed processing eliminates batch size limitations
- Steady state after one cycle with <1% variability
Target: Affinity capture steps (Protein A, mixed-mode) Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
CaptureSMB® — Performance Gains
| Metric | Result |
|---|---|
| Processing speed | Up to 3× faster than batch |
| Protein A resin consumption | Up to 50% reduction |
| Buffer consumption | Up to 50% reduction |
| Productivity | 2–4× higher vs. single-column batch |
| Intermediate storage | Reduced — continuous output eliminates hold steps |
| Process control | AutomAb® enables continuous 24/7 operation |
| Scale-up variability | <1% — steady state after one cycle |
One column loads while the other elutes — continuous output, maximum resin utilization, consistent quality.
Integrated Batch — Two-Step Purification
Couple two chromatography steps without intermediate handling:
- Parallel or in-series column configurations
- Two chromatography modes run consecutively (e.g., IEX then HIC)
- On-board buffer in-line dilution (BID option) for pH adjustment
- Eliminates intermediate hold tanks and manual handling
- Reduces process time, QC burden, and facility footprint
Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
Batch Chromatography
Single-column batch purification:
| Mode | Applications |
|---|---|
| Isocratic | Affinity capture, SEC, desalting |
| Gradient | IEX, HIC, mixed-mode polishing |
- Linear gradient from 5% to 95% in batch mode
- Multiple fraction collection outlets
- Full UV/flow/pressure/pH/conductivity monitoring
Buffer In-line Dilution (BID)
On-board dilution of buffer concentrates and CIP solutions:
- Third pump (Pump C) delivers dilution buffer at controlled ratio
- Static mixer ensures homogeneous blending
- Enables pH adjustment between capture and polish steps
- Supports sequential processing for pool-less multi-step chromatography
Requires: BID option (Pump C, inlet valves, static mixer, sensors)
Regulatory Compliance & Documentation
Certifications
- UL-approved electrical panels
- CE marking available including PED compliance
- Developed under GAMP 5 framework
- Complies with FDA 21 CFR Part 11 regulations
Standards & Directives
- ASME-BPE for all stainless steel product contact welds
- FDA-approved USP Class VI materials and seals
- UL-approved electrical panels
- CE marking with PED compliance
Materials & Documentation
- All wetted materials selected for biopharmaceutical compatibility and chemical resistance
- Full traceability with MTRs and certificates of compliance
- Product contact surface roughness: < 0.8 µm Ra (SF5 spec: ≤ 20 Ra EP)
- Turnover Package (TOP) with comprehensive QA/QC documentation
TOP includes: MTRs, certificates of compliance, pressure test reports, passivation reports, weld documentation (logs, inspection reports, procedures, coupon logs, isometrics), slope verification, operation and maintenance manuals, as-built drawings (PDF and native CAD/Solidworks).
Specifications
System Models
| Parameter | TWIN 300 | TWIN 500 | TWIN 1000 | TWIN 2000 |
|---|---|---|---|---|
| Flow Rate | 0.03 – 3.33 L/min | 0.08 – 8.33 L/min | 0.15 – 18.9 L/min | 0.5 – 36 L/min |
| Column ID | 10–20 cm | 20–45 cm | 30–60 cm | 60–100 cm |
| Max Operating Pressure | 7.5 bar | 7.5 bar | 7.5 bar | 7.5 bar |
| Best For | Pilot / clinical | Mid-scale GMP | Large-scale GMP | Maximum capacity |
General Specifications
| Specification | Value |
|---|---|
| Max Operating Pressure | 7.5 bar (0.75 MPa / 109 psi) |
| Operating Temperature | 4–25 °C ambient; 4–40 °C process |
| Design | Sanitary, CIP-compatible (NaOH 1M) |
| Wetted Materials | SS 316L or Hastelloy, PTFE, EPDM (USP Class VI) |
| Surface Finish | < 0.8 µm Ra (product contact), SF5 spec: ≤ 20 Ra EP |
| Control System | Rockwell CompactLogix PLC |
| Processes | Batch, Integrated Batch, CaptureSMB® |
Physical Specifications
| Model | Length | Width | Height | Approx. Weight |
|---|---|---|---|---|
| TWIN 300 | 218 cm | 127 cm | 203 cm | 2494 kg |
| TWIN 500 | 299 cm | 165 cm | 198 cm | 3055 kg |
| TWIN 1000 (Pump) | 360 cm | 140 cm | 230 cm | 4455 kg |
| TWIN 1000 (Process) | 140 cm | 90 cm | 200 cm | 1364 kg |
| TWIN 2000 (Pump) | 381 cm | 152 cm | 230 cm | 4763 kg |
| TWIN 2000 (Process) | 147 cm | 101 cm | 200 cm | 1543 kg |
Pumps (LEWA ecodos)
| Configuration | 2× triplex diaphragm pumps (3× with BID option) |
| Diaphragm | Sandwich PTFE with rupture detection |
| Materials | USP Class VI certified, FDA approved |
| Features | Automatic stroke adjustment, nearly pulse-free flow |
Detectors & Sensors
| UV Detection | 4-channel, multi-wavelength DAD, 200–600 nm, 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
| Flow Meters (×2) | Coriolis |
| Pressure (×8) | Transmitters throughout flow path, 0–13.8 bar, ±1% FS |
| pH | On waste and collection outlets, 0–13, ±0.15 unit |
| Conductivity | On waste and collection outlets, 0–200 mS/cm, ±1% of measured value |
| Temperature | Post-column, 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump and pre-column (ultrasonic) |
Valves & Flow Path
| Valve Actuation | Pneumatic diaphragm valves |
| Valve Materials | 316L SS body, PTFE/EPDM diaphragm |
| Product Contact | SF5 spec: ≤ 20 Ra EP |
| Non-Product Contact | SF1 spec: ≤ 20 Ra MP |
| Column Connections | Sanitary tri-clamp |
| CIP | Dedicated inlet and outlet manifolds |
Software & Automation
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB® with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
| Data Integrity | 21 CFR Part 11, audit trail, electronic signatures |
User Interface
| HMI | 24″ industrial touchscreen, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
Optional Modules
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Technologies
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Applications
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
Resources
- All Media Types
- Peer-Reviewed Publications
Scale-Up of Twin-Column Periodic Counter-Current Chromatography for MAb Purification, BioProcess Int.
CaptureSMB scale-up from laboratory to manufacturing scale establishes engineering principles for continuous capture process transfer.
Service & Support
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
FAQ
A complete Contichrom® TWIN LPLC – Capture system includes:
- Complete sanitary skid assembly with mobile frame (levelers and casters)
- 2× LEWA ecodos triplex pumps with sandwich diaphragms and rupture detection
- Full inlet and outlet pneumatic valve network (sanitary design)
- Dual wavelength UV detectors (280 nm, 303 nm)
- Post-column pH and conductivity sensors
- 2× Coriolis flow meters + 8× pressure transmitters
- Pre-pump and pre-column air sensors
- CIP inlet and outlet manifolds
- 24″ HMI with industrial PC and control software preloaded
- Rockwell CompactLogix PLC control system
- Comprehensive TOP documentation package
- Factory Acceptance Testing (FAT) — up to 5 days
- One week on-site startup support and training
Customer provides: Columns, filter elements, chromatography resin, external piping, utilities connections.
| Feature | TWIN HPLC | TWIN LPLC Capture | TWIN LPLC Polishing |
|---|---|---|---|
| Design | Industrial (non-sanitary) | Sanitary | Sanitary |
| Pressure | 80 bar | 7.5 bar (20 bar opt.) | 7.5 bar (20 bar opt.) |
| Core Process | MCSGP (polishing) | CaptureSMB® (capture) | MCSGP (polishing) |
| HP Valves | YMC fast-acting | Standard pneumatic | Standard pneumatic |
| Pumps | 4× LEWA ecoflow | 2× (3×) LEWA ecodos | 4× LEWA ecodos |
| Molecules | Synthetic peptides, oligos | Biologics (mAbs, AAV, ADCs) | Biologics (mAbs, AAV, ADCs) |
The TWIN LPLC – Capture is the right choice for affinity capture of biopharmaceuticals where sanitary design and CIP capability are required.
| Model | Column ID | Flow Rate | Best For |
|---|---|---|---|
| TWIN 300 | 10–20 cm | 0.03 – 3.33 L/min | Pilot production, clinical manufacturing |
| TWIN 500 | 20–45 cm | 0.08 – 8.33 L/min | Mid-scale commercial production |
| TWIN 1000 | 30–60 cm | 0.15 – 18.9 L/min | Large-scale commercial production |
| TWIN 2000 | 60–100 cm | 0.5 – 36 L/min | Maximum capacity production |
Contact YMC to discuss your throughput requirements and optimal system selection.
- Floor space: Dimensions vary by model (contact YMC for GA drawings)
- Power: Model-dependent (contact YMC for specifications)
- Utilities: Process air, water, compressed air, drain, network connection
- Ambient temperature: 4–25 °C
- Process temperature: 4–40 °C
Note: System must be uncrated, leveled, and connected to utilities before YMC on-site work begins.
- Methods developed on Contichrom CUBE transfer directly to the TWIN LPLC
- Same CaptureSMB® principles and AutomAb® control at both scales
- Scale-up at over 100× verified and published
- Steady state after one cycle with <1% variability
- YMC ChromaCon provides process transfer support
- FAT — Up to 5 days at YMC facility
- On-site startup — One week including commissioning and system walkdown
- Training — 1 full day or 2 half-days covering operation and maintenance
- Remote support — HMS Ewon remote access for troubleshooting and training
- Warranty: 12 months from installation or 18 months from shipment (whichever first)
- Global service: YMC operations worldwide, LEWA support in 80 countries
- Remote access: Built-in capability for automation troubleshooting
- Components: Non-proprietary with global distribution for local acquisition
- Maintenance: No special tools required for standard maintenance
Yes — customization options include:
- Buffer in-line dilution (BID) with additional pump
- Additional inlet valves (up to 6 on Pump A, B, or C)
- Additional outlet/fraction valves (up to 5 fraction + 1 waste)
- Pre-column analytics (pH and conductivity)
- Single or dual filter housings
- Bubble traps
- CIP manifolds for aseptic single-use bag connection
Contact YMC ChromaCon for custom configuration pricing.
Overview
GMP-Ready Continuous Capture for Biopharmaceutical Manufacturing
The Contichrom® TWIN LPLC – Capture is a sanitary chromatography system for continuous capture of biologics from pilot to large-scale GMP manufacturing.
- Twin-column continuous capture (CaptureSMB® with AutomAb®)
- Up to 3× faster processing, 50% less resin and buffer vs. batch
- Sanitary design with CIP capability for biopharmaceutical production
- SS 316L or Hastelloy flow paths, 7.5 bar maximum operating pressure
- 21 CFR Part 11 compliant software with full audit trail
One System, Multiple Processes
Batch AND continuous capture on a single sanitary skid:
| Mode | Technology |
|---|---|
| Batch | Single-column isocratic and gradient |
| 2D Integrated Batch | Two-step purification with in-line dilution (BID) |
| Continuous Capture | CaptureSMB® with AutomAb® |
- Switch seamlessly between batch and CaptureSMB® modes
- Buffer in-line dilution (BID) option for on-board pH adjustment
- Eliminates duplicate equipment — saves space and capital
Patented CaptureSMB Technology
Twin-column continuous capture maximizing resin binding capacity:
| Metric | Value |
|---|---|
| Speed | Up to 3× faster than batch |
| Resin & buffer | Up to 50% reduction |
| Productivity | 2–4× vs. single-column batch |
- Two columns alternate loading and elution — continuous output
- Columns in series so the second captures breakthrough from the first
- Near-complete resin utilization eliminates re-chromatography
AutomAb® - Dynamic Process Control
AutomAb® monitors UV breakthrough in real time and adjusts column switching automatically:
- Detects product breakthrough and triggers switching at the optimal point
- Compensates for feed variability, column aging, and resin degradation
- Delivers consistent capture efficiency without operator intervention
- Enables robust, continuous 24/7 manufacturing
- Steady state reached after only one cycle with <1% variability
Comprehensive Application Range
Production-scale capture for biopharmaceuticals:
| Application | CaptureSMB® | Integrated Batch |
|---|---|---|
| mAbs & Antibody Variants | ✓ | ✓ |
| Viral Vectors (AAV) | ✓ | ✓ |
| Antibody-drug Conjugates | ✓ | ✓ |
| Recombinant Proteins | ✓ | ✓ |
- All processes run on the same sanitary hardware
- AutomAb® dynamic control across continuous operations
Scalable from Lab to Production
Part of the Contichrom® platform with established transfer protocols:
| System | Flow Rate | Column ID |
|---|---|---|
| CUBE 30/100 | 0.1–100 mL/min | 0.5–5 cm |
| TWIN LPLC 300 | 0.03 – 3.33 L/min | 10–20 cm |
| TWIN LPLC 500 | 0.08 – 8.33 L/min | 20–45 cm |
| TWIN LPLC 1000 | 0.15 – 18.9 L/min | 30–60 cm |
| TWIN LPLC 2000 | 0.5 – 36 L/min | 60–100 cm |
- Scale-up from CUBE at over 100× verified and published
- Same CaptureSMB® and AutomAb® control at every scale
Sanitary Design for Bioprocessing
Purpose-built for biopharmaceutical manufacturing environments:
- Fully sanitary flow path with drainable design and CIP compatibility
- ASME-BPE compliant stainless steel welds on all product contact surfaces
- SS 316L or Hastelloy flow path materials
- SF5 spec product contact tubing (≤ 20 Ra EP)
- Designed for NaOH 1M CIP and compatible with single-use aseptic interfaces
- Maximum operating pressure of 7.5 bar — optimal for affinity and LP resins
Designed for GMP Compliance
Built to meet stringent biopharmaceutical manufacturing requirements:
- Developed under the GAMP 5 framework
- 21 CFR Part 11 compliant software with audit trail
- Comprehensive Turnover Package (TOP) with ASME-BPE compliant welds
- USP Class VI materials and FDA-approved seals
- UL-approved panels, CE marking including PED compliance
TOP includes: MTRs, pressure test reports, passivation reports, weld documentation, as-built drawings.
Production-Grade Hardware
A complete skid-mounted system with mobile frame:
- 2× Pumps (base) — LEWA ecodos triplex with rupture detection
- 3rd Pump (BID option) — Buffer in-line dilution
- Dual UV Detectors — 4-Channel Adjustable wavelength (200-600 nm), 0.5 mm path length
- 2× Coriolis flow meters + 8× pressure transmitters
- pH, conductivity & temperature — Post-column standard
- Air sensors — Pre-pump and pre-column
- Pneumatic valves — Sanitary design, fast-acting at low pressure
- 24″ HMI — Industrial touchscreen with FactoryTalk View SE
CIP-Ready Design
The Contichrom® TWIN LPLC – Capture is designed for cleaning-in-place:
- Dedicated CIP inlet and outlet manifolds integrated into the valve network
- Fully drainable flow path design minimizes carryover between campaigns
- Compatible with NaOH 1M CIP protocols
- Optional single-use aseptic interface for minimally classified suites
- Reduces turnaround time and supports multi-product facility operation
How it works
Sanitary Hardware for GMP Biopharmaceutical Capture Chromatography
The Contichrom TWIN LPLC – Capture is a complete sanitary skid-mounted unit for GMP manufacturing:
- Mobile frame with levelers and non-marking caster wheels
- 316L stainless steel frame with mechanically polished welds
- Sanitary flow path designed for drainability and CIP
- Two column positions for CaptureSMB and single-column batch
- Operating temperature: 4–25 °C ambient, 4–40 °C process
LEWA Ecodos Triplex Pumps
Industry-leading LEWA ecodos triplex pumps for precision and reliability:
| Pump | Role |
|---|---|
| Pump A | Feed delivery / Load buffer |
| Pump B | Elution / Wash / Equilibration |
| Pump C (optional) | Buffer in-line dilution (BID) |
- Triplex configuration for nearly pulse-free flow
- Sandwich diaphragm with rupture detection alarm
- Automatic stroke adjustment for optimal performance
- PTFE diaphragms — USP Class VI certified, FDA approved
- Base system includes 2 pumps; 3rd pump available with BID option
Pneumatic Valve Network
Sanitary pneumatic valves — fast-acting at low pressure:
- Inlet Selection Valves — Multiple ports per pump for automated buffer/feed switching
- Column Switching Valves — For CaptureSMB interconnected and parallel configurations
- Fraction Outlet Valves — Product and waste routing with drain connection
- CIP Manifolds — Dedicated inlet and outlet for cleaning-in-place
- Materials: 316L SS body, PTFE/EPDM diaphragm, SF5 spec product contact (≤ 20 Ra EP)
- Sanitary design
Dual Wavelength UV Detectors
Two post-column UV sensors for real-time monitoring and AutomAb® control:
| Parameter | Specification |
|---|---|
| Type | 4-channel, multi-wavelength DAD, 200–600 nm |
| Path length | 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
- Provides the UV breakthrough signals that enables AutomAb® dynamic process control
- Critical for consistent CaptureSMB® capture efficiency
In-Line Process Sensors
Comprehensive real-time monitoring:
| Sensor | Quantity | Specification |
|---|---|---|
| Coriolis Flow Meters | 2 | Flow monitoring and control |
| Pressure Transmitters | 8 | 0–13.8 bar, ±1% FS |
| pH | Post-column (x2) | 0–13 pH, ±0.15 unit |
| Conductivity | Post-column (x2) | 0–200 mS/cm, ±1% of measured value |
| Temperature | Per column | 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump + pre-column | Ultrasonic detection |
Column Management
Flexible column configurations for production scale:
- 2 column positions for CaptureSMB® twin-column operation
- Column ID range: 10–100 cm (depending on model)
- Low-pressure operation Max 7.5 bar — optimized for affinity resins
- Sanitary tri-clamp connections for column attachment
- Single-column batch mode available
Human-Machine Interface (HMI)
System control via industrial PC running FactoryTalk View SE:
| Component | Specification |
|---|---|
| Touchscreen | 24″ industrial HMI, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
- Real-time process visualization, recipe management, batch reporting
GMP-Grade Flow Path
Every product-contact surface selected for biopharmaceutical compatibility:
| Component | Materials |
|---|---|
| Product Contact Tubing | 316L SS or Hastelloy, ≤ 20 Ra EP (SF5 spec) |
| Non-Product Contact Tubing | 316L SS, ≤ 20 Ra MP (SF1 spec) |
| Process Valves | 316L SS body, PTFE/EPDM diaphragm |
| Pump Diaphragms | PTFE (USP Class VI, FDA approved) |
- ASME-BPE compliant welds, drainable design, CIP-compatible
- Surface roughness < 0.8 µm Ra on wetted metallic parts
PLC-Based Control System
Industrial automation platform:
| Component | Specification |
|---|---|
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
Optional Hardware
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Process Capabilities
Continuous Capture for Biopharmaceutical Production
The Contichrom TWIN LPLC – Capture is optimized for twin-column continuous capture:
- CaptureSMB® with AutomAb® — Continuous capture
- 2D Integrated Batch — Two-step purification with in-line dilution (BID option)
- Batch — Single-column isocratic and gradient operation
- All accessible from a single sanitary GMP-ready platform
CaptureSMB® with AutomAb® — Continuous Capture
Twin-column continuous capture maximizing resin binding capacity:
- Two identical columns alternate between loading and elution
- Columns in series — second column captures breakthrough from the first
- AutomAb® detects UV breakthrough and triggers column switching
- Near-complete utilization of resin binding capacity
- Continuous feed processing eliminates batch size limitations
- Steady state after one cycle with <1% variability
Target: Affinity capture steps (Protein A, mixed-mode) Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
CaptureSMB® — Performance Gains
| Metric | Result |
|---|---|
| Processing speed | Up to 3× faster than batch |
| Protein A resin consumption | Up to 50% reduction |
| Buffer consumption | Up to 50% reduction |
| Productivity | 2–4× higher vs. single-column batch |
| Intermediate storage | Reduced — continuous output eliminates hold steps |
| Process control | AutomAb® enables continuous 24/7 operation |
| Scale-up variability | <1% — steady state after one cycle |
One column loads while the other elutes — continuous output, maximum resin utilization, consistent quality.
Integrated Batch — Two-Step Purification
Couple two chromatography steps without intermediate handling:
- Parallel or in-series column configurations
- Two chromatography modes run consecutively (e.g., IEX then HIC)
- On-board buffer in-line dilution (BID option) for pH adjustment
- Eliminates intermediate hold tanks and manual handling
- Reduces process time, QC burden, and facility footprint
Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
Batch Chromatography
Single-column batch purification:
| Mode | Applications |
|---|---|
| Isocratic | Affinity capture, SEC, desalting |
| Gradient | IEX, HIC, mixed-mode polishing |
- Linear gradient from 5% to 95% in batch mode
- Multiple fraction collection outlets
- Full UV/flow/pressure/pH/conductivity monitoring
Buffer In-line Dilution (BID)
On-board dilution of buffer concentrates and CIP solutions:
- Third pump (Pump C) delivers dilution buffer at controlled ratio
- Static mixer ensures homogeneous blending
- Enables pH adjustment between capture and polish steps
- Supports sequential processing for pool-less multi-step chromatography
Requires: BID option (Pump C, inlet valves, static mixer, sensors)
Regulatory Compliance & Documentation
Certifications
- UL-approved electrical panels
- CE marking available including PED compliance
- Developed under GAMP 5 framework
- Complies with FDA 21 CFR Part 11 regulations
Standards & Directives
- ASME-BPE for all stainless steel product contact welds
- FDA-approved USP Class VI materials and seals
- UL-approved electrical panels
- CE marking with PED compliance
Materials & Documentation
- All wetted materials selected for biopharmaceutical compatibility and chemical resistance
- Full traceability with MTRs and certificates of compliance
- Product contact surface roughness: < 0.8 µm Ra (SF5 spec: ≤ 20 Ra EP)
- Turnover Package (TOP) with comprehensive QA/QC documentation
TOP includes: MTRs, certificates of compliance, pressure test reports, passivation reports, weld documentation (logs, inspection reports, procedures, coupon logs, isometrics), slope verification, operation and maintenance manuals, as-built drawings (PDF and native CAD/Solidworks).
Specifications
System Models
| Parameter | TWIN 300 | TWIN 500 | TWIN 1000 | TWIN 2000 |
|---|---|---|---|---|
| Flow Rate | 0.03 – 3.33 L/min | 0.08 – 8.33 L/min | 0.15 – 18.9 L/min | 0.5 – 36 L/min |
| Column ID | 10–20 cm | 20–45 cm | 30–60 cm | 60–100 cm |
| Max Operating Pressure | 7.5 bar | 7.5 bar | 7.5 bar | 7.5 bar |
| Best For | Pilot / clinical | Mid-scale GMP | Large-scale GMP | Maximum capacity |
General Specifications
| Specification | Value |
|---|---|
| Max Operating Pressure | 7.5 bar (0.75 MPa / 109 psi) |
| Operating Temperature | 4–25 °C ambient; 4–40 °C process |
| Design | Sanitary, CIP-compatible (NaOH 1M) |
| Wetted Materials | SS 316L or Hastelloy, PTFE, EPDM (USP Class VI) |
| Surface Finish | < 0.8 µm Ra (product contact), SF5 spec: ≤ 20 Ra EP |
| Control System | Rockwell CompactLogix PLC |
| Processes | Batch, Integrated Batch, CaptureSMB® |
Physical Specifications
| Model | Length | Width | Height | Approx. Weight |
|---|---|---|---|---|
| TWIN 300 | 218 cm | 127 cm | 203 cm | 2494 kg |
| TWIN 500 | 299 cm | 165 cm | 198 cm | 3055 kg |
| TWIN 1000 (Pump) | 360 cm | 140 cm | 230 cm | 4455 kg |
| TWIN 1000 (Process) | 140 cm | 90 cm | 200 cm | 1364 kg |
| TWIN 2000 (Pump) | 381 cm | 152 cm | 230 cm | 4763 kg |
| TWIN 2000 (Process) | 147 cm | 101 cm | 200 cm | 1543 kg |
Pumps (LEWA ecodos)
| Configuration | 2× triplex diaphragm pumps (3× with BID option) |
| Diaphragm | Sandwich PTFE with rupture detection |
| Materials | USP Class VI certified, FDA approved |
| Features | Automatic stroke adjustment, nearly pulse-free flow |
Detectors & Sensors
| UV Detection | 4-channel, multi-wavelength DAD, 200–600 nm, 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
| Flow Meters (×2) | Coriolis |
| Pressure (×8) | Transmitters throughout flow path, 0–13.8 bar, ±1% FS |
| pH | On waste and collection outlets, 0–13, ±0.15 unit |
| Conductivity | On waste and collection outlets, 0–200 mS/cm, ±1% of measured value |
| Temperature | Post-column, 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump and pre-column (ultrasonic) |
Valves & Flow Path
| Valve Actuation | Pneumatic diaphragm valves |
| Valve Materials | 316L SS body, PTFE/EPDM diaphragm |
| Product Contact | SF5 spec: ≤ 20 Ra EP |
| Non-Product Contact | SF1 spec: ≤ 20 Ra MP |
| Column Connections | Sanitary tri-clamp |
| CIP | Dedicated inlet and outlet manifolds |
Software & Automation
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB® with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
| Data Integrity | 21 CFR Part 11, audit trail, electronic signatures |
User Interface
| HMI | 24″ industrial touchscreen, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
Optional Modules
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Technologies
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Applications
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
Resources
- All Media Types
- Peer-Reviewed Publications
Scale-Up of Twin-Column Periodic Counter-Current Chromatography for MAb Purification, BioProcess Int.
CaptureSMB scale-up from laboratory to manufacturing scale establishes engineering principles for continuous capture process transfer.
Service & Support
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
FAQ
A complete Contichrom® TWIN LPLC – Capture system includes:
- Complete sanitary skid assembly with mobile frame (levelers and casters)
- 2× LEWA ecodos triplex pumps with sandwich diaphragms and rupture detection
- Full inlet and outlet pneumatic valve network (sanitary design)
- Dual wavelength UV detectors (280 nm, 303 nm)
- Post-column pH and conductivity sensors
- 2× Coriolis flow meters + 8× pressure transmitters
- Pre-pump and pre-column air sensors
- CIP inlet and outlet manifolds
- 24″ HMI with industrial PC and control software preloaded
- Rockwell CompactLogix PLC control system
- Comprehensive TOP documentation package
- Factory Acceptance Testing (FAT) — up to 5 days
- One week on-site startup support and training
Customer provides: Columns, filter elements, chromatography resin, external piping, utilities connections.
| Feature | TWIN HPLC | TWIN LPLC Capture | TWIN LPLC Polishing |
|---|---|---|---|
| Design | Industrial (non-sanitary) | Sanitary | Sanitary |
| Pressure | 80 bar | 7.5 bar (20 bar opt.) | 7.5 bar (20 bar opt.) |
| Core Process | MCSGP (polishing) | CaptureSMB® (capture) | MCSGP (polishing) |
| HP Valves | YMC fast-acting | Standard pneumatic | Standard pneumatic |
| Pumps | 4× LEWA ecoflow | 2× (3×) LEWA ecodos | 4× LEWA ecodos |
| Molecules | Synthetic peptides, oligos | Biologics (mAbs, AAV, ADCs) | Biologics (mAbs, AAV, ADCs) |
The TWIN LPLC – Capture is the right choice for affinity capture of biopharmaceuticals where sanitary design and CIP capability are required.
| Model | Column ID | Flow Rate | Best For |
|---|---|---|---|
| TWIN 300 | 10–20 cm | 0.03 – 3.33 L/min | Pilot production, clinical manufacturing |
| TWIN 500 | 20–45 cm | 0.08 – 8.33 L/min | Mid-scale commercial production |
| TWIN 1000 | 30–60 cm | 0.15 – 18.9 L/min | Large-scale commercial production |
| TWIN 2000 | 60–100 cm | 0.5 – 36 L/min | Maximum capacity production |
Contact YMC to discuss your throughput requirements and optimal system selection.
- Floor space: Dimensions vary by model (contact YMC for GA drawings)
- Power: Model-dependent (contact YMC for specifications)
- Utilities: Process air, water, compressed air, drain, network connection
- Ambient temperature: 4–25 °C
- Process temperature: 4–40 °C
Note: System must be uncrated, leveled, and connected to utilities before YMC on-site work begins.
- Methods developed on Contichrom CUBE transfer directly to the TWIN LPLC
- Same CaptureSMB® principles and AutomAb® control at both scales
- Scale-up at over 100× verified and published
- Steady state after one cycle with <1% variability
- YMC ChromaCon provides process transfer support
- FAT — Up to 5 days at YMC facility
- On-site startup — One week including commissioning and system walkdown
- Training — 1 full day or 2 half-days covering operation and maintenance
- Remote support — HMS Ewon remote access for troubleshooting and training
- Warranty: 12 months from installation or 18 months from shipment (whichever first)
- Global service: YMC operations worldwide, LEWA support in 80 countries
- Remote access: Built-in capability for automation troubleshooting
- Components: Non-proprietary with global distribution for local acquisition
- Maintenance: No special tools required for standard maintenance
Yes — customization options include:
- Buffer in-line dilution (BID) with additional pump
- Additional inlet valves (up to 6 on Pump A, B, or C)
- Additional outlet/fraction valves (up to 5 fraction + 1 waste)
- Pre-column analytics (pH and conductivity)
- Single or dual filter housings
- Bubble traps
- CIP manifolds for aseptic single-use bag connection
Contact YMC ChromaCon for custom configuration pricing.
Overview
GMP-Ready Continuous Capture for Biopharmaceutical Manufacturing
The Contichrom® TWIN LPLC – Capture is a sanitary chromatography system for continuous capture of biologics from pilot to large-scale GMP manufacturing.
- Twin-column continuous capture (CaptureSMB® with AutomAb®)
- Up to 3× faster processing, 50% less resin and buffer vs. batch
- Sanitary design with CIP capability for biopharmaceutical production
- SS 316L or Hastelloy flow paths, 7.5 bar maximum operating pressure
- 21 CFR Part 11 compliant software with full audit trail
One System, Multiple Processes
Batch AND continuous capture on a single sanitary skid:
| Mode | Technology |
|---|---|
| Batch | Single-column isocratic and gradient |
| 2D Integrated Batch | Two-step purification with in-line dilution (BID) |
| Continuous Capture | CaptureSMB® with AutomAb® |
- Switch seamlessly between batch and CaptureSMB® modes
- Buffer in-line dilution (BID) option for on-board pH adjustment
- Eliminates duplicate equipment — saves space and capital
Patented CaptureSMB Technology
Twin-column continuous capture maximizing resin binding capacity:
| Metric | Value |
|---|---|
| Speed | Up to 3× faster than batch |
| Resin & buffer | Up to 50% reduction |
| Productivity | 2–4× vs. single-column batch |
- Two columns alternate loading and elution — continuous output
- Columns in series so the second captures breakthrough from the first
- Near-complete resin utilization eliminates re-chromatography
AutomAb® - Dynamic Process Control
AutomAb® monitors UV breakthrough in real time and adjusts column switching automatically:
- Detects product breakthrough and triggers switching at the optimal point
- Compensates for feed variability, column aging, and resin degradation
- Delivers consistent capture efficiency without operator intervention
- Enables robust, continuous 24/7 manufacturing
- Steady state reached after only one cycle with <1% variability
Comprehensive Application Range
Production-scale capture for biopharmaceuticals:
| Application | CaptureSMB® | Integrated Batch |
|---|---|---|
| mAbs & Antibody Variants | ✓ | ✓ |
| Viral Vectors (AAV) | ✓ | ✓ |
| Antibody-drug Conjugates | ✓ | ✓ |
| Recombinant Proteins | ✓ | ✓ |
- All processes run on the same sanitary hardware
- AutomAb® dynamic control across continuous operations
Scalable from Lab to Production
Part of the Contichrom® platform with established transfer protocols:
| System | Flow Rate | Column ID |
|---|---|---|
| CUBE 30/100 | 0.1–100 mL/min | 0.5–5 cm |
| TWIN LPLC 300 | 0.03 – 3.33 L/min | 10–20 cm |
| TWIN LPLC 500 | 0.08 – 8.33 L/min | 20–45 cm |
| TWIN LPLC 1000 | 0.15 – 18.9 L/min | 30–60 cm |
| TWIN LPLC 2000 | 0.5 – 36 L/min | 60–100 cm |
- Scale-up from CUBE at over 100× verified and published
- Same CaptureSMB® and AutomAb® control at every scale
Sanitary Design for Bioprocessing
Purpose-built for biopharmaceutical manufacturing environments:
- Fully sanitary flow path with drainable design and CIP compatibility
- ASME-BPE compliant stainless steel welds on all product contact surfaces
- SS 316L or Hastelloy flow path materials
- SF5 spec product contact tubing (≤ 20 Ra EP)
- Designed for NaOH 1M CIP and compatible with single-use aseptic interfaces
- Maximum operating pressure of 7.5 bar — optimal for affinity and LP resins
Designed for GMP Compliance
Built to meet stringent biopharmaceutical manufacturing requirements:
- Developed under the GAMP 5 framework
- 21 CFR Part 11 compliant software with audit trail
- Comprehensive Turnover Package (TOP) with ASME-BPE compliant welds
- USP Class VI materials and FDA-approved seals
- UL-approved panels, CE marking including PED compliance
TOP includes: MTRs, pressure test reports, passivation reports, weld documentation, as-built drawings.
Production-Grade Hardware
A complete skid-mounted system with mobile frame:
- 2× Pumps (base) — LEWA ecodos triplex with rupture detection
- 3rd Pump (BID option) — Buffer in-line dilution
- Dual UV Detectors — 4-Channel Adjustable wavelength (200-600 nm), 0.5 mm path length
- 2× Coriolis flow meters + 8× pressure transmitters
- pH, conductivity & temperature — Post-column standard
- Air sensors — Pre-pump and pre-column
- Pneumatic valves — Sanitary design, fast-acting at low pressure
- 24″ HMI — Industrial touchscreen with FactoryTalk View SE
CIP-Ready Design
The Contichrom® TWIN LPLC – Capture is designed for cleaning-in-place:
- Dedicated CIP inlet and outlet manifolds integrated into the valve network
- Fully drainable flow path design minimizes carryover between campaigns
- Compatible with NaOH 1M CIP protocols
- Optional single-use aseptic interface for minimally classified suites
- Reduces turnaround time and supports multi-product facility operation
How it works
Sanitary Hardware for GMP Biopharmaceutical Capture Chromatography
The Contichrom TWIN LPLC – Capture is a complete sanitary skid-mounted unit for GMP manufacturing:
- Mobile frame with levelers and non-marking caster wheels
- 316L stainless steel frame with mechanically polished welds
- Sanitary flow path designed for drainability and CIP
- Two column positions for CaptureSMB and single-column batch
- Operating temperature: 4–25 °C ambient, 4–40 °C process
LEWA Ecodos Triplex Pumps
Industry-leading LEWA ecodos triplex pumps for precision and reliability:
| Pump | Role |
|---|---|
| Pump A | Feed delivery / Load buffer |
| Pump B | Elution / Wash / Equilibration |
| Pump C (optional) | Buffer in-line dilution (BID) |
- Triplex configuration for nearly pulse-free flow
- Sandwich diaphragm with rupture detection alarm
- Automatic stroke adjustment for optimal performance
- PTFE diaphragms — USP Class VI certified, FDA approved
- Base system includes 2 pumps; 3rd pump available with BID option
Pneumatic Valve Network
Sanitary pneumatic valves — fast-acting at low pressure:
- Inlet Selection Valves — Multiple ports per pump for automated buffer/feed switching
- Column Switching Valves — For CaptureSMB interconnected and parallel configurations
- Fraction Outlet Valves — Product and waste routing with drain connection
- CIP Manifolds — Dedicated inlet and outlet for cleaning-in-place
- Materials: 316L SS body, PTFE/EPDM diaphragm, SF5 spec product contact (≤ 20 Ra EP)
- Sanitary design
Dual Wavelength UV Detectors
Two post-column UV sensors for real-time monitoring and AutomAb® control:
| Parameter | Specification |
|---|---|
| Type | 4-channel, multi-wavelength DAD, 200–600 nm |
| Path length | 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
- Provides the UV breakthrough signals that enables AutomAb® dynamic process control
- Critical for consistent CaptureSMB® capture efficiency
In-Line Process Sensors
Comprehensive real-time monitoring:
| Sensor | Quantity | Specification |
|---|---|---|
| Coriolis Flow Meters | 2 | Flow monitoring and control |
| Pressure Transmitters | 8 | 0–13.8 bar, ±1% FS |
| pH | Post-column (x2) | 0–13 pH, ±0.15 unit |
| Conductivity | Post-column (x2) | 0–200 mS/cm, ±1% of measured value |
| Temperature | Per column | 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump + pre-column | Ultrasonic detection |
Column Management
Flexible column configurations for production scale:
- 2 column positions for CaptureSMB® twin-column operation
- Column ID range: 10–100 cm (depending on model)
- Low-pressure operation Max 7.5 bar — optimized for affinity resins
- Sanitary tri-clamp connections for column attachment
- Single-column batch mode available
Human-Machine Interface (HMI)
System control via industrial PC running FactoryTalk View SE:
| Component | Specification |
|---|---|
| Touchscreen | 24″ industrial HMI, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
- Real-time process visualization, recipe management, batch reporting
GMP-Grade Flow Path
Every product-contact surface selected for biopharmaceutical compatibility:
| Component | Materials |
|---|---|
| Product Contact Tubing | 316L SS or Hastelloy, ≤ 20 Ra EP (SF5 spec) |
| Non-Product Contact Tubing | 316L SS, ≤ 20 Ra MP (SF1 spec) |
| Process Valves | 316L SS body, PTFE/EPDM diaphragm |
| Pump Diaphragms | PTFE (USP Class VI, FDA approved) |
- ASME-BPE compliant welds, drainable design, CIP-compatible
- Surface roughness < 0.8 µm Ra on wetted metallic parts
PLC-Based Control System
Industrial automation platform:
| Component | Specification |
|---|---|
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
Optional Hardware
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Process Capabilities
Continuous Capture for Biopharmaceutical Production
The Contichrom TWIN LPLC – Capture is optimized for twin-column continuous capture:
- CaptureSMB® with AutomAb® — Continuous capture
- 2D Integrated Batch — Two-step purification with in-line dilution (BID option)
- Batch — Single-column isocratic and gradient operation
- All accessible from a single sanitary GMP-ready platform
CaptureSMB® with AutomAb® — Continuous Capture
Twin-column continuous capture maximizing resin binding capacity:
- Two identical columns alternate between loading and elution
- Columns in series — second column captures breakthrough from the first
- AutomAb® detects UV breakthrough and triggers column switching
- Near-complete utilization of resin binding capacity
- Continuous feed processing eliminates batch size limitations
- Steady state after one cycle with <1% variability
Target: Affinity capture steps (Protein A, mixed-mode) Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
CaptureSMB® — Performance Gains
| Metric | Result |
|---|---|
| Processing speed | Up to 3× faster than batch |
| Protein A resin consumption | Up to 50% reduction |
| Buffer consumption | Up to 50% reduction |
| Productivity | 2–4× higher vs. single-column batch |
| Intermediate storage | Reduced — continuous output eliminates hold steps |
| Process control | AutomAb® enables continuous 24/7 operation |
| Scale-up variability | <1% — steady state after one cycle |
One column loads while the other elutes — continuous output, maximum resin utilization, consistent quality.
Integrated Batch — Two-Step Purification
Couple two chromatography steps without intermediate handling:
- Parallel or in-series column configurations
- Two chromatography modes run consecutively (e.g., IEX then HIC)
- On-board buffer in-line dilution (BID option) for pH adjustment
- Eliminates intermediate hold tanks and manual handling
- Reduces process time, QC burden, and facility footprint
Molecules: mAbs, antibody variants, viral vectors (AAV), ADCs, recombinant proteins
Batch Chromatography
Single-column batch purification:
| Mode | Applications |
|---|---|
| Isocratic | Affinity capture, SEC, desalting |
| Gradient | IEX, HIC, mixed-mode polishing |
- Linear gradient from 5% to 95% in batch mode
- Multiple fraction collection outlets
- Full UV/flow/pressure/pH/conductivity monitoring
Buffer In-line Dilution (BID)
On-board dilution of buffer concentrates and CIP solutions:
- Third pump (Pump C) delivers dilution buffer at controlled ratio
- Static mixer ensures homogeneous blending
- Enables pH adjustment between capture and polish steps
- Supports sequential processing for pool-less multi-step chromatography
Requires: BID option (Pump C, inlet valves, static mixer, sensors)
Regulatory Compliance & Documentation
Certifications
- UL-approved electrical panels
- CE marking available including PED compliance
- Developed under GAMP 5 framework
- Complies with FDA 21 CFR Part 11 regulations
Standards & Directives
- ASME-BPE for all stainless steel product contact welds
- FDA-approved USP Class VI materials and seals
- UL-approved electrical panels
- CE marking with PED compliance
Materials & Documentation
- All wetted materials selected for biopharmaceutical compatibility and chemical resistance
- Full traceability with MTRs and certificates of compliance
- Product contact surface roughness: < 0.8 µm Ra (SF5 spec: ≤ 20 Ra EP)
- Turnover Package (TOP) with comprehensive QA/QC documentation
TOP includes: MTRs, certificates of compliance, pressure test reports, passivation reports, weld documentation (logs, inspection reports, procedures, coupon logs, isometrics), slope verification, operation and maintenance manuals, as-built drawings (PDF and native CAD/Solidworks).
Specifications
System Models
| Parameter | TWIN 300 | TWIN 500 | TWIN 1000 | TWIN 2000 |
|---|---|---|---|---|
| Flow Rate | 0.03 – 3.33 L/min | 0.08 – 8.33 L/min | 0.15 – 18.9 L/min | 0.5 – 36 L/min |
| Column ID | 10–20 cm | 20–45 cm | 30–60 cm | 60–100 cm |
| Max Operating Pressure | 7.5 bar | 7.5 bar | 7.5 bar | 7.5 bar |
| Best For | Pilot / clinical | Mid-scale GMP | Large-scale GMP | Maximum capacity |
General Specifications
| Specification | Value |
|---|---|
| Max Operating Pressure | 7.5 bar (0.75 MPa / 109 psi) |
| Operating Temperature | 4–25 °C ambient; 4–40 °C process |
| Design | Sanitary, CIP-compatible (NaOH 1M) |
| Wetted Materials | SS 316L or Hastelloy, PTFE, EPDM (USP Class VI) |
| Surface Finish | < 0.8 µm Ra (product contact), SF5 spec: ≤ 20 Ra EP |
| Control System | Rockwell CompactLogix PLC |
| Processes | Batch, Integrated Batch, CaptureSMB® |
Physical Specifications
| Model | Length | Width | Height | Approx. Weight |
|---|---|---|---|---|
| TWIN 300 | 218 cm | 127 cm | 203 cm | 2494 kg |
| TWIN 500 | 299 cm | 165 cm | 198 cm | 3055 kg |
| TWIN 1000 (Pump) | 360 cm | 140 cm | 230 cm | 4455 kg |
| TWIN 1000 (Process) | 140 cm | 90 cm | 200 cm | 1364 kg |
| TWIN 2000 (Pump) | 381 cm | 152 cm | 230 cm | 4763 kg |
| TWIN 2000 (Process) | 147 cm | 101 cm | 200 cm | 1543 kg |
Pumps (LEWA ecodos)
| Configuration | 2× triplex diaphragm pumps (3× with BID option) |
| Diaphragm | Sandwich PTFE with rupture detection |
| Materials | USP Class VI certified, FDA approved |
| Features | Automatic stroke adjustment, nearly pulse-free flow |
Detectors & Sensors
| UV Detection | 4-channel, multi-wavelength DAD, 200–600 nm, 0.5 mm path (exchangeable for 0.1, 0.3, or 1 mm) |
| Flow Meters (×2) | Coriolis |
| Pressure (×8) | Transmitters throughout flow path, 0–13.8 bar, ±1% FS |
| pH | On waste and collection outlets, 0–13, ±0.15 unit |
| Conductivity | On waste and collection outlets, 0–200 mS/cm, ±1% of measured value |
| Temperature | Post-column, 0–100 °C, ±0.25 °C at 25 °C |
| Air Sensors | Pre-pump and pre-column (ultrasonic) |
Valves & Flow Path
| Valve Actuation | Pneumatic diaphragm valves |
| Valve Materials | 316L SS body, PTFE/EPDM diaphragm |
| Product Contact | SF5 spec: ≤ 20 Ra EP |
| Non-Product Contact | SF1 spec: ≤ 20 Ra MP |
| Column Connections | Sanitary tri-clamp |
| CIP | Dedicated inlet and outlet manifolds |
Software & Automation
| PLC Platform | Rockwell CompactLogix |
| HMI Runtime | FactoryTalk View SE |
| Process Control | CaptureSMB® with AutomAb® |
| Database | Microsoft SQL Server |
| Historian | YMC Server Historian |
| Reports | YMC Server Reports (auto-generated) |
| Remote Access | HMS Ewon module (client-enabled) |
| Data Integrity | 21 CFR Part 11, audit trail, electronic signatures |
User Interface
| HMI | 24″ industrial touchscreen, panel-mounted |
| Industrial PC | Preloaded with control software |
| OS | Windows 11 Professional |
Optional Modules
| Option | Specification |
|---|---|
| Buffer In-line Dilution (BID) | Pump C + inlet valves + static mixer + sensors |
| Additional Inlet Valves | Up to 6 per pump |
| Additional Outlet Valves | Up to 5 fraction + 1 waste |
| Filter Housings | Single or dual with valve manifolds |
| Bubble Traps | 2 with valve manifold and vent valves |
| CIP Manifolds | Aseptic single-use bag connection |
| Software Customizations | Handshake with upstream/downstream equipment, additional control loops, external valve/equipment control |
Technologies
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Single-column purification with full method flexibility — gradient, isocratic, step elution. The foundation for process development and the starting point for continuous workflows.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Automate sequential purification across multiple columns and chemistries in a single run. ChromIQ® handles fraction transfer, timing, and method switching.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Twin-column continuous loading maximizes resin utilization and throughput. AutomAb® dynamically controls breakthrough — adapting in real time to feed variability.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Real-time UV-based control that adapts your continuous process to feed and column variability — eliminating the need for fixed, conservative operating parameters.
Applications
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
CaptureSMB® with AutomAb® for mAbs & antibody variants: maximize productivity and resin utilization, while slashing buffer consumption.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
From capture through polishing, Contichrom® integrates multiple chromatography steps into automated 2D/3D workflows — reducing hands-on time and intermediate handling.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
MCSGP with AutoPeak® is ideally suited for DAR control, achieving precise drug-antibody ratios with higher yield than batch chromatography.
Resources
- All Media Types
- Peer-Reviewed Publications
Scale-Up of Twin-Column Periodic Counter-Current Chromatography for MAb Purification, BioProcess Int.
CaptureSMB scale-up from laboratory to manufacturing scale establishes engineering principles for continuous capture process transfer.
Service & Support
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
See Contichrom® in action. On-site, at our facility, or remote — get a first-hand look at what our chromatography systems and software can do.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Hands-on operator training, advanced application workshops, and expert consulting — customised to your team's experience and your specific Contichrom® applications.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Calibrated mechanistic models built from your batch data — simulate and optimize batch, MCSGP, or CaptureSMB® processes computationally, before running a single experiment.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Try a Contichrom® system in your own lab before committing to a purchase. Full technical support and training included — evaluate the technology on your terms.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Quantified performance comparison. Run your molecule on our Contichrom® systems and benchmark CaptureSMB® or MCSGP against your existing batch process.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
Preventive maintenance subscriptions and on-site repair services to keep your Contichrom® running at peak performance. Remote technical support available worldwide.
FAQ
A complete Contichrom® TWIN LPLC – Capture system includes:
- Complete sanitary skid assembly with mobile frame (levelers and casters)
- 2× LEWA ecodos triplex pumps with sandwich diaphragms and rupture detection
- Full inlet and outlet pneumatic valve network (sanitary design)
- Dual wavelength UV detectors (280 nm, 303 nm)
- Post-column pH and conductivity sensors
- 2× Coriolis flow meters + 8× pressure transmitters
- Pre-pump and pre-column air sensors
- CIP inlet and outlet manifolds
- 24″ HMI with industrial PC and control software preloaded
- Rockwell CompactLogix PLC control system
- Comprehensive TOP documentation package
- Factory Acceptance Testing (FAT) — up to 5 days
- One week on-site startup support and training
Customer provides: Columns, filter elements, chromatography resin, external piping, utilities connections.
| Feature | TWIN HPLC | TWIN LPLC Capture | TWIN LPLC Polishing |
|---|---|---|---|
| Design | Industrial (non-sanitary) | Sanitary | Sanitary |
| Pressure | 80 bar | 7.5 bar (20 bar opt.) | 7.5 bar (20 bar opt.) |
| Core Process | MCSGP (polishing) | CaptureSMB® (capture) | MCSGP (polishing) |
| HP Valves | YMC fast-acting | Standard pneumatic | Standard pneumatic |
| Pumps | 4× LEWA ecoflow | 2× (3×) LEWA ecodos | 4× LEWA ecodos |
| Molecules | Synthetic peptides, oligos | Biologics (mAbs, AAV, ADCs) | Biologics (mAbs, AAV, ADCs) |
The TWIN LPLC – Capture is the right choice for affinity capture of biopharmaceuticals where sanitary design and CIP capability are required.
| Model | Column ID | Flow Rate | Best For |
|---|---|---|---|
| TWIN 300 | 10–20 cm | 0.03 – 3.33 L/min | Pilot production, clinical manufacturing |
| TWIN 500 | 20–45 cm | 0.08 – 8.33 L/min | Mid-scale commercial production |
| TWIN 1000 | 30–60 cm | 0.15 – 18.9 L/min | Large-scale commercial production |
| TWIN 2000 | 60–100 cm | 0.5 – 36 L/min | Maximum capacity production |
Contact YMC to discuss your throughput requirements and optimal system selection.
- Floor space: Dimensions vary by model (contact YMC for GA drawings)
- Power: Model-dependent (contact YMC for specifications)
- Utilities: Process air, water, compressed air, drain, network connection
- Ambient temperature: 4–25 °C
- Process temperature: 4–40 °C
Note: System must be uncrated, leveled, and connected to utilities before YMC on-site work begins.
- Methods developed on Contichrom CUBE transfer directly to the TWIN LPLC
- Same CaptureSMB® principles and AutomAb® control at both scales
- Scale-up at over 100× verified and published
- Steady state after one cycle with <1% variability
- YMC ChromaCon provides process transfer support
- FAT — Up to 5 days at YMC facility
- On-site startup — One week including commissioning and system walkdown
- Training — 1 full day or 2 half-days covering operation and maintenance
- Remote support — HMS Ewon remote access for troubleshooting and training
- Warranty: 12 months from installation or 18 months from shipment (whichever first)
- Global service: YMC operations worldwide, LEWA support in 80 countries
- Remote access: Built-in capability for automation troubleshooting
- Components: Non-proprietary with global distribution for local acquisition
- Maintenance: No special tools required for standard maintenance
Yes — customization options include:
- Buffer in-line dilution (BID) with additional pump
- Additional inlet valves (up to 6 on Pump A, B, or C)
- Additional outlet/fraction valves (up to 5 fraction + 1 waste)
- Pre-column analytics (pH and conductivity)
- Single or dual filter housings
- Bubble traps
- CIP manifolds for aseptic single-use bag connection
Contact YMC ChromaCon for custom configuration pricing.