Skip to content
  • Chromatography Solutions
    By Application By System By Service
    Peptides Oligonucleotides mAbs & Antibody Variants Antibody-drug Conjugates Recombinant Proteins Viral Vectors (AAV) Small Molecules & Nutraceuticals Impurity Isolation
    Contichrom® CUBE
    CUBE 30 (36 mL/min) CUBE 100 (100 mL/min) CUBE Software CUBE Accessories
    Contichrom® PILOT
    PILOT 300X (300 mL/min)
    Contichrom® TWIN HPLC
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Capture
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Polishing
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Demos & Introductions Training & Consulting System Rentals Process Modeling Feasibility Studies Custom Purification Maintenance & Repair
    By Application
    Peptides Oligonucleotides mAbs & Antibody Variants Antibody-drug Conjugates Recombinant Proteins Viral Vectors (AAV) Small Molecules & Nutraceuticals Impurity Isolation
    By System
    Contichrom® CUBE
    CUBE 30 (36 mL/min) CUBE 100 (100 mL/min) CUBE Software CUBE Accessories
    Contichrom® PILOT
    PILOT 300X (300 mL/min)
    Contichrom® TWIN HPLC
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Capture
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Polishing
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    By Service
    Demos & Introductions Training & Consulting System Rentals Process Modeling Feasibility Studies Custom Purification Maintenance & Repair
  • Learning Center
    Technologies Resource Library Research Highlights Educational Articles
    Batch Chromatography Multi-Dimensional Chromatography (2D/3D) Continuous Capture (CaptureSMB®) Continuous Polishing (MCSGP) Continuous Enrichment (N-Rich®) Dynamic Process Control (AutoPeak® & AutomAb®)
    Application Notes Webinars & Videos Process Guides & Manuals Peer-Reviewed Publications Brochures & Datasheets White Papers
    Peptide Purification Oligonucleotide Purification
    Fundamentals of Preparative Chromatography Troubleshooting & Best Practices (Coming Soon)
    Technologies
    Batch Chromatography Multi-Dimensional Chromatography (2D/3D) Continuous Capture (CaptureSMB®) Continuous Polishing (MCSGP) Continuous Enrichment (N-Rich®) Dynamic Process Control (AutoPeak® & AutomAb®)
    Resource Library
    Application Notes Webinars & Videos Process Guides & Manuals Peer-Reviewed Publications Brochures & Datasheets White Papers
    Research Highlights
    Peptide Purification Oligonucleotide Purification
    Educational Articles
    Fundamentals of Preparative Chromatography Troubleshooting & Best Practices (Coming Soon)
    • About ChromaCon
    • News & Events
    • Distributors
    • Join our team
    • Contact
  • English
  • Deutsch
Get in Touch

Reversed-Phase MCSGP for GalNAc-Conjugated Oligonucleotides

Purification is where oligonucleotide yield is lost, and the synthesis has to be sized to cover it. Converting a reversed-phase batch method for a GalNAc-conjugated gapmer to twin-column MCSGP lifted recovery from 52.7% to 91.6% at the same purity — enough to shrink the synthesis step by 42.5% for the same daily output.

Oligo Purification 07 Sep 2026
Oligonucleotide purification — illustration

In this article

  • 1. Why This Study Matters
  • 2. The Study at a Glance
  • 3. What the Yield Buys
  • 4. Designing the Process
  • 5. What Six Cycles Showed
  • 6. Full Results
  • 7. What It Means for Manufacturing
  • 8. Key Terms
  • 9. FAQs

Research Highlight

Breaking the Yield–Purity Trade-Off for GalNAc Oligonucleotides

A reversed-phase batch purification of a GalNAc-cluster-conjugated gapmer recovered just over half the product at specification. Run as a continuous twin-column process on the same chemistry, it recovered 91.6% — enough to shrink the oligonucleotide synthesis step by 42.5% for the same daily output.

Purification of a GalNAc-cluster-conjugated oligonucleotide by reversed-phase twin-column continuous chromatography

Richard Weldon, Jörg Lill, Martin Olbrich, Pascal Schmidt and Thomas Müller-Späth

Journal of Chromatography A 2022, 1663, 462734 · Available online 12 December 2021
DOI: 10.1016/j.chroma.2021.462734 · Open access, CC BY-NC-ND 4.0

Read the full article View on ScienceDirect

The authors declare no known competing financial interests or personal relationships that could have appeared to influence the work. Jörg Lill, Martin Olbrich and Pascal Schmidt are at F. Hoffmann-La Roche Ltd., which funded the study; Richard Weldon and Thomas Müller-Späth are at YMC ChromaCon.

Citation (BibTeX)
@article{weldon2022galnac,
  title   = {Purification of a GalNAc-cluster-conjugated oligonucleotide by
             reversed-phase twin-column continuous chromatography},
  author  = {Weldon, Richard and Lill, J{\"o}rg and Olbrich, Martin
             and Schmidt, Pascal and M{\"u}ller-Sp{\"a}th, Thomas},
  journal = {Journal of Chromatography A},
  volume  = {1663},
  pages   = {462734},
  year    = {2022},
  doi     = {10.1016/j.chroma.2021.462734}
}
  • 1. Why This Study Matters
  • 2. The Study at a Glance
  • 3. What the Yield Buys
  • 4. Designing the Process
  • 5. What Six Cycles Showed
  • 6. Full Results
  • 7. What It Means for Manufacturing
  • 8. Key Terms
  • 9. FAQs

The problem has a familiar shape. Widen the collection window and yield goes up while purity falls; narrow it and purity rises while yield falls. For an oligonucleotide, impurities differing from the target by a single nucleotide tend to co-elute with it, which makes that trade-off an expensive one. The study reports a clinical-grade purity target of more than 90% as typically costing between 20% and 50% of the product, followed by expensive re-chromatography to claw some of it back.

That loss does not stay in the chromatography suite. Solid-phase synthesis is the major cost driver in oligonucleotide production, so whatever the purification gives up has to be made in the first place.

This study takes a reversed-phase batch method for a GalNAc-cluster-conjugated DNA-LNA gapmer and converts it to twin-column MCSGP. Yield rises from 52.70% to 91.58% at the same purity — 94.2 area%, from a 77.5 area% crude — with productivity and buffer consumption essentially unchanged.

It is described as the first evaluation of MCSGP for a GalNAc-cluster-conjugated gapmer in reversed-phase mode, and it carries the result through to a scale-up estimate: what that yield is worth in kilograms of synthesis per day.

1. Why This Study Matters: Synthesis Is Where the Cost Is

Oligonucleotide production runs in four major steps — solid-phase synthesis, chromatographic purification, desalting by diafiltration or precipitation, and isolation by freeze drying. The study is direct about where the money sits: oligonucleotide synthesis is currently the major cost driver, and any loss of product in the downstream steps has a major impact on overall manufacturing costs.

It also frames the scale problem. Demand for production capacity is expanding rapidly, but oligonucleotide therapeutics are yet to be manufactured at multi-ton scale and no compound-dedicated production facilities exist — which is why pharmaceutical companies and CMOs are actively evaluating platform technologies that will optimize production and reduce costs.

Why the separation is hard

Synthesis delivers roughly 60% to 80% desired product alongside a mixture of impurities, and they fall into three families:

  • Shortmers Sequences missing one or more nucleotides (N-x), left behind by incomplete chemical coupling reactions during elongation.
  • Full-length product impurities Molecules of the right length carrying a defect — cyanoethyl modification, phosphate impurity, depurination — produced by modifying side reactions.
  • Longmers Sequences with extra material, such as lambdamers and branchmers, arising from impurities present in the starting raw materials.

N-1 and N+1 are singled out as particularly challenging: one nucleotide shorter or longer than the target, chemically almost identical, and so tending to co-elute. Even after considerable optimization, a preparative batch method leaves impurities significantly co-eluting with the product, especially for highly phosphorothiolated sequences. Meeting specification therefore means fractionating carefully and accepting that the side fractions are either discarded or re-chromatographed at cost — lower productivity, more buffer, intermediate storage, extra quality control.

Recycling, but not the usual kind

MCSGP is not the only way to recycle. Steady-state recycling and closed-loop recycling do it too, and the paper draws a specific distinction. In those single-column processes the chromatographic profile passes through a pump every cycle, which is possibly detrimental to product stability and limits the process to isocratic operation. In MCSGP the recycled side fractions are fully adsorbed onto the second column and then subjected to renewed gradient elution, so product and impurities pass through a pump only during the load step. The authors argue this makes MCSGP well suited to complex molecules such as oligonucleotides.

2. The Study at a Glance

The molecule is a DNA-LNA gapmer conjugated to a bislysin GalNAc cluster — the sugar ligand that transports synthetic oligonucleotides into hepatocytes by endocytosis, allowing the development of treatments targeting diseases of the liver. It was assembled by standard phosphoramidite chemistry on solid phase at a 2.0 mmol scale, then conjugated to the GalNAc cluster in solution phase. The crude entered purification at 77.5 area% by RP-HPLC.

91.6%

Product yield at specification, against 52.7% for the batch benchmark

94.2

Area% product purity, enriched from a 77.5 area% crude

42.5%

Smaller oligonucleotide synthesis step for the same daily output, in the scale-up estimate

1.3

g/Lresin/h productivity — essentially unchanged from the batch process

What was run, and on what

The batch benchmark

A preparative reversed-phase method on a YMC Triart Prep C8-S column, 150 × 10 mm i.d., 10 µm, 12 nm, at 45 °C. Mobile phases were acetonitrile against 0.2 M sodium acetate. Load was 2.52 g per liter of resin; higher loads gave insufficient product purity, though those data are not shown. Elution fractions were analyzed by HPLC for purity and by Nanodrop for concentration.

The continuous process

MCSGP on a Contichrom CUBE 30 with two columns of the same C8 resin and the same 15 cm bed height, at 45 °C, with UV recorded at 300 nm after each column outlet. The method was designed from the batch chromatogram using the MCSGP Wizard and run for six cycles, giving twelve product elutions.

Two deliberate simplifications distinguish the continuous method from its batch parent. The wash after loading was dropped, because the strong recycling step effectively substitutes for it. And regeneration, which the batch process performs after every elution, was applied only at the end of the MCSGP run — with no evident negative impact on process performance.

3. What the Yield Buys Upstream

At a matched purity of roughly 94 area%, the batch process recovered 52.70% of the product loaded and MCSGP recovered 91.58%. The interesting question is what that difference is worth once the process is scaled, and the study answers it with a simplified estimate built around a single 60 cm batch column producing 1.3 kg of product a day.

Crude in Product out 77.5% product 3,200 g 1 × 60 cm 42 L resin 1,307 g 77.5% product 3,200 g 2 × 60 cm 70 L resin 2,270 g 77.5% product 1,841 g 2 × 45 cm 42 L resin 1,307 g
  • Product contained in the crude
  • Impurities in the crude
  • Product recovered

The reference process. A single 60 cm column takes 3,200 g of crude a day and returns 1,307 g of product. The crude is 77.5% product, so the darker band is what was available to recover — and just over half of it makes it out. The synthesis has to be sized to cover the rest.

Crude in
3,200 g/day
Product out
1,307 g/day
Resin
42 L
Buffer
12,534 L/day

Scenarios as reported in Table 4 of the study, drawn to a single mass scale so the bars compare directly. These are simplified scale-up estimates rather than demonstrated production runs. Red marks the product, following the color convention used in Figures 1 and 2 of the paper.

The study is even-handed about the first scenario. Two 60 cm columns hold 70 L of resin between them against 42 L for the single batch column, so the extra output is not free. The authors point out that a batch process using the same total resin volume could deliver 2,614 g/day — but would need twice the feed, 6,400 g/day, to do it. The comparison that isolates the yield advantage is the third: same product out, same total resin, 42.5% less crude in.

A Simple Analogy

A distiller takes a heart cut from each run and sets aside the heads and tails at either end. Cut the heart narrow and the spirit is clean but there is little of it; cut it wide and there is more, carrying off-notes with it. It is the same choice a chromatographer makes at the fraction collector.

Distillers do not throw the heads and tails away — they go back into the next charge. That is what the recycling phases do here. Because the side fractions return to the second column, the heart can be cut narrow for purity without the yield being written off.

4. Designing the Continuous Process

MCSGP is designed by dividing a batch gradient chromatogram into four phases that make up one switch. The batch run is not merely a benchmark in this study; it is the design template, which is why the paper notes that the batch process should already reach the target purity with good productivity and acceptable buffer consumption before conversion begins. A batch process with a yield between 20% and 80% is described as a good starting point.

  • P1 — columns in parallel Weakly adsorbing impurities elute from column 1 to waste, while column 2 is regenerated ready for loading.
  • P2 — columns interconnected The mixture of weakly adsorbing impurities and product elutes from column 1 and is recycled, with in-line dilution, directly onto column 2.
  • P3 — columns in parallel Pure product is collected from column 1 while fresh feed is loaded onto column 2. To hold a switch-to-switch steady state, the quantity of new feed applied is in equilibrium with the product removed — a load the software calculates from the batch chromatogram and fraction analysis.
  • P4 — columns interconnected The mixture of product and strongly adsorbing impurities is recycled onto column 2 in the same way as P2. The columns then swap positions and the sequence repeats.

Setting the boundaries is where the judgment sits. P3 was positioned to achieve the target purity of more than 94 area%, calculated by the wizard, and P2 and P4 were positioned to fully recycle the lower-purity side fractions. Because N-1 and N+1 are structurally so close to the target and correspondingly hard to remove, their abundance across the peak was checked as well, so that the product collection window could be placed to minimize them.

The wizard then calculated the in-line dilution flow rates needed to dilute the modifier concentration of the eluate back to initial loading conditions — essential if product recycled from one column is to fully re-adsorb on the other — along with the loading parameters required to establish a cyclic steady state. It produced three methods: a startup that preloads the upstream column as a batch process would, a main method of six MCSGP cycles, and a shutdown consisting of one switch with a final product elution but no feeding.

5. What Six Cycles Showed

Six cycles were run, each comprising two switches, for twelve product elutions in total. The question a continuous process has to answer is whether it settles, and whether anything accumulates while it does.

The height of the UV profile inside the P3 product collection window stayed consistent from cycle 1 to cycle 6, which indicates that material entering the system was in equilibrium with material leaving it. The visible changes across early cycles were in the P2 and P4 recycling windows, where impurities accumulate and take several cycles to reach steady state.

Accumulation in the recycling windows is expected. It matters only if impurities build toward the product pool: if they accumulate in the direction of P3, purity falls cycle to cycle and the product can drop below specification. Placing the phase boundaries appropriately during design is what avoids or controls that.

All six cycles were therefore analyzed, by HPLC for purity and Nanodrop for concentration. Concentration held at around 2.7 g/L and total purity stayed consistently above 94 area% across the run, and neither N-1 nor N+1 showed accumulation. On that basis the authors conclude that the process parameters are well designed with respect to product quality. Comparing the final pooled product from all six cycles against the input material shows enrichment from 77.5 area% to 94.2 area%.

Why the reported figures are steady-state values

One thing to read carefully. Startup and shutdown both cost performance, because the load applied during startup contains more product than is recovered in the final shutdown, and the shutdown does not recycle its side fractions — making it analogous to a batch run in terms of product loss. With only six cycles run, the authors restricted the performance comparison to steady state, meaning process performance if the number of cycles were infinite. They describe this as the best-case scenario, and state that in practice a run of more than 20 cycles would be very similar.

6. Full Results

Swipe the table sideways to see the feed, batch and MCSGP columns.

Metric Feed Batch MCSGP
GalNAc-conjugated DNA-LNA gapmer specification >94 area% · MCSGP figures are steady-state values
Product purity (area%) 77.4894.2294.16
Impurity N-1 (area%) 3.360.930.87
Impurity N+1 (area%) 4.231.221.41
Yield (%) —52.7091.58
Productivity (g/Lresin/h) —1.301.33
Buffer consumption (L/g) —9.599.22
Product concentration (g/L) —3.252.71
Load per cycle (g/L resin) —2.521.83

Values from Table 3 of the study, rearranged. Weldon, Lill, Olbrich, Schmidt and Müller-Späth, J. Chromatogr. A 2022, 1663, 462734, published under CC BY-NC-ND 4.0.

Where the two processes differ, and where they do not

Yield is the change. Almost everything else is close to unchanged: purity is matched by design at roughly 94 area%, productivity is 1.33 against 1.30 g/Lresin/h, and buffer consumption is 9.22 against 9.59 L per gram of product. N-1 came out marginally lower in MCSGP and N+1 marginally higher.

Two figures moved the wrong way, and both are acknowledged. Product concentration was 17% lower in MCSGP, which the authors flag as leaving scope to reduce eluate volumes. And the MCSGP load was lower than the batch load, 1.83 against 2.52 g per liter of resin — not because that was optimal but because load optimization was not part of the study. Batch experiments qualitatively indicated that small increases in load led to further yield loss, which suggests the binding capacity of the resin was already being used to a great extent.

Scale-up scenarios

Swipe the table sideways to see all three scenarios.

Parameter Batch MCSGP, same feed MCSGP, same output
Feed input at 77.5% purity (g/day) 3,2003,200 1,841
Production amount (g/day) 1,3072,270 1,307
Column inner diameter 60 cm2 × 60 cm 2 × 45 cm
Required resin volume 42 L2 × 35 L 2 × 21 L
Pump size on skid 15 L/min16 L/min 8 L/min
Daily buffer demand 12,534 L20,929 L 12,050 L

Values from Table 4 of the study, rearranged. These are simplified scale-up estimates, not demonstrated production runs.

7. What It Means for Manufacturing

The scale-up estimate is where the yield figure becomes an operational argument. Producing the same 1.3 kg of product a day from 1,841 g of crude instead of 3,200 g means the preceding steps, including oligonucleotide synthesis, can be downscaled by 42.5% — or, read the other way, the same amount of product can be made 42.5% faster.

The equipment picture is mixed. In the same-output scenario the two MCSGP columns hold the same total resin as the single batch column, at a smaller inner diameter, and the smaller diameter allows smaller pumps on the skid to reach the same linear flow rate. Because MCSGP uses similar equipment with a comparable footprint to batch chromatography, the authors consider it feasible to equip existing facilities.

Beyond yield, the paper lists three further advantages. Re-chromatography of side fractions is no longer required, which removes a step that improves batch yields but decreases overall productivity, increases buffer consumption and demands manual handling and storage space. The analytical burden can fall: a stable batch process requires a minimum of three pools to be collected and analyzed, more when product collection is less robust and more again after re-chromatography, whereas MCSGP typically generates a single product pool per cycle and it may be sufficient to pool and analyze every few cycles. And less human intervention is needed during production, so fewer personnel are required.

Against that, the paper names its own trade-off plainly: elevated equipment and validation complexity, since an MCSGP setup uses two columns and approximately doubles the amount of hardware.

An equivalent conversion in anion exchange mode, on a conjugated siRNA sense strand, is reported in a companion study in this series. For the platform view of where MCSGP fits in an oligonucleotide workflow, see oligonucleotide purification with MCSGP.

What the study does not claim

  • The MCSGP figures are steady-state values. Only six cycles were run, and the comparison excludes the performance impact of startup and shutdown. The authors describe this as the best-case scenario — process performance as if the cycle count were infinite — and state that a run of more than 20 cycles would be very similar. Reported yield, productivity and buffer consumption should be read on that basis.
  • Load was not optimized. MCSGP ran at 1.83 g/L resin against 2.52 for batch. Load optimization was not part of the study, and batch experiments qualitatively suggested small load increases cost yield.
  • Product concentration was 17% lower. The authors identify this as scope for method improvement to reduce eluate volumes.
  • N+1 was slightly higher. 1.41 area% in the MCSGP pool against 1.22 in the batch pool, although N-1 was slightly lower at 0.87 against 0.93.
  • More hardware, more validation. The paper states the trade-off directly: two columns and approximately double the hardware components bring elevated equipment and validation complexity.
  • Scale-up is an estimate. The three scenarios are a simplified calculation from the measured performance, not demonstrated production runs.
  • Funding and affiliations. The study was funded by F. Hoffmann-La Roche Ltd., where three of the five authors work; the other two are at YMC ChromaCon, which commercializes MCSGP. The authors declare no known competing financial interests or personal relationships that could have appeared to influence the work.

8. Key Terms in This Study (Glossary)

Term Definition
Center cut The central portion of a batch elution peak that meets purity specification and is collected as product. The fractions either side of it are the side fractions.
Closed-loop recycling (CLR) A single-column recycling technique in which the chromatographic profile passes back through a pump each cycle. Limited to isocratic operation, and the repeated pump passage may affect product stability.
Cyclic steady state The condition in which each MCSGP cycle reproduces the previous one, with material entering the system in equilibrium with material leaving it.
Gapmer An antisense oligonucleotide design with a central DNA segment flanked by modified nucleotides — here locked nucleic acid — which confer stability while the central gap remains active against the RNA target.
GalNAc cluster An N-acetylgalactosamine ligand conjugated to an oligonucleotide, providing transport into hepatocytes by endocytosis and so enabling treatments targeting diseases of the liver.
In-line dilution Dilution of the recycled stream between interconnected columns, returning the modifier concentration to initial loading conditions so the recycled product fully re-adsorbs on the downstream column.
LNA Locked nucleic acid, a nucleotide analogue with a constrained ribose ring, used to raise the stability and target affinity of synthetic oligonucleotides.
Longmer A sequence longer than the target, such as a lambdamer or branchmer, arising from impurities in the starting raw materials.
MCSGP Multicolumn Countercurrent Solvent Gradient Purification: a continuous twin-column chromatography process that recycles impure side fractions internally, so that only product meeting specification leaves the system.
N-1 and N+1 Impurities one nucleotide shorter and one nucleotide longer than the target. Structurally very close to the product and correspondingly difficult to separate from it.
P1 to P4 The four phases of one MCSGP switch: weak impurities to waste, weak-side recycling, product collection with simultaneous feeding, and strong-side recycling.
Phosphorothioate A backbone modification replacing an oxygen with sulfur to resist degradation. Highly phosphorothiolated sequences are noted as especially prone to impurities co-eluting with the product.
Re-chromatography Re-running lower-purity side fractions to recover further product. It raises batch yield but lowers productivity, raises buffer consumption and adds handling, storage and quality control.
Shortmer A sequence missing one or more nucleotides, denoted N-x, produced by incomplete chemical coupling during synthesis.
Startup and shutdown The methods that begin and end an MCSGP run. Startup preloads the first column; shutdown performs a final elution without feeding and without recycling its side fractions.
Steady-state recycling (SSR) A single-column recycling technique related to closed-loop recycling, sharing the same limitation that the profile passes through a pump each cycle.
Switch and cycle A switch is one product elution from one column, made up of phases P1 to P4. One cycle is two switches, with one product elution from each of the twin columns.
Yield–purity trade-off The inverse relationship in batch chromatography between how much product is collected and how pure the pool is, set by separation performance and where the collection boundaries are drawn.

9. Frequently Asked Questions

Yes. This study reports the first evaluation of MCSGP for a GalNAc-cluster-conjugated DNA-LNA gapmer in reversed-phase mode. Starting from an established batch method on the same C8 resin and the same acetonitrile and sodium acetate mobile phases, the continuous process reached 91.58% yield at 94.16 area% purity, against 52.70% yield at 94.22 area% for the batch benchmark.

In this case, yield rose from 52.70% to 91.58% at matched purity — a relative improvement of 73.6%. The size of the gain depends on the batch process it starts from: a batch process with a yield between 20% and 80% is described as a good starting point for MCSGP development, so a batch method that already recovers most of its product has less room to improve.

Synthesis. Oligonucleotide synthesis is the major cost driver in production, and the scale of it is set by how much product the purification is expected to lose. In the study’s scale-up estimate, the same 1,307 g of daily product could be made from 1,841 g of crude instead of 3,200 g — allowing the preceding steps, including synthesis, to be downscaled by 42.5%. Read the other way, the same output could be produced 42.5% faster.

Not in this study. Productivity was 1.33 g/Lresin/h for MCSGP against 1.30 for batch, and buffer consumption 9.22 L/g against 9.59 — both essentially unchanged. Two figures did move the wrong way: product concentration was 17% lower, and the N+1 impurity was marginally higher at 1.41 area% against 1.22.

In steady-state recycling and closed-loop recycling, the chromatographic profile passes through a pump every cycle, which is possibly detrimental to product stability and limits those processes to isocratic operation. In MCSGP the recycled side fractions are fully adsorbed onto a second column and then subjected to renewed gradient elution, so product and impurities pass through a pump only during the load step. The authors argue this makes MCSGP well suited to complex molecules such as oligonucleotides.

More than were run here, to see the full benefit. Startup and shutdown both reduce overall performance, because the startup load contains more product than the shutdown recovers and the shutdown does not recycle its side fractions. The paper states that running more than 20 cycles is ideal to minimize their relative impact. Because only six cycles were run in this study, the reported performance figures describe the steady state rather than a whole-run average.

The chemistry stays the same. This study used the same C8 stationary phase and the same acetonitrile and sodium acetate mobile phases as the batch method, with two deliberate simplifications: the wash after loading was dropped, since the strong recycling step substitutes for it, and regeneration was applied only at the end of the run rather than after every elution. The equipment is the trade-off — MCSGP uses two columns and approximately doubles the hardware components, bringing elevated equipment and validation complexity, though the footprint is comparable to batch chromatography.

Yes. It is published open access in Journal of Chromatography A and can be read and downloaded free of charge. Note that it carries a CC BY-NC-ND 4.0 license rather than the CC BY used by many open-access papers, so reuse is limited to non-commercial purposes and does not extend to derivative works. Supplementary material covering the specific batch and MCSGP method parameters and the analytical gradient is available alongside the article.

Related Articles

Continuous Anion Exchange Purification of a Conjugated siRNA
Oligo Purification 27 Aug 2026

Continuous Anion Exchange Purification of a Conjugated siRNA

An established anion exchange batch method for a conjugated siRNA sense strand, converted to continuous twin-column MCSGP: 13 cycles, 27 product elutions, and yield up from 80% to 93% at unchanged purity — plus a software-aided route from batch chromatogram to running method.

ChromaCon AG
Technoparkstrasse 1
8005 Zürich, Switzerland
+41 (0)44 445 20 10
ISO 9001:2015 certified quality management
English | Deutsch
  • Applications Overview
  • Antibody-drug Conjugates
  • Impurity Isolation
  • mAbs & Antibody Variants
  • Small Molecules & Nutraceuticals
  • Oligonucleotides
  • Peptides
  • Recombinant Proteins
  • Viral Vectors (AAV)
  • Systems Overview
  • Contichrom® CUBE
  • Contichrom® PILOT
  • Contichrom® TWIN HPLC
  • Contichrom® TWIN LPLC – Capture
  • Contichrom® TWIN LPLC – Polishing
  • Technologies Overview
  • Batch Chromatography
  • Continuous Capture (CaptureSMB®)
  • Continuous Enrichment (N-Rich®)
  • Continuous Polishing (MCSGP)
  • Dynamic Process Control (AutoPeak® & AutomAb®)
  • Multi-Dimensional Chromatography (2D/3D)
  • Services Overview
  • Custom Purification
  • Demos & Introductions
  • Feasibility Studies
  • Maintenance & Repair
  • Process Modeling
  • System Rentals
  • Training & Consulting
  • About ChromaCon
  • News & Events
  • Distributors
  • Careers
  • Contact
  • Resource Library
  • Educational Articles
© 2026 ChromaCon, A YMC Company. All rights reserved. ChromaCon is a proud member of the YMC Group. | YMC ChromaCon is a business unit of YMC Co., Ltd.
  • AI Image Use
  • Imprint
  • Privacy Policy
  • Cookie Policy
  • Terms and conditions
  • Chromatography Solutions
    By Application By System By Service
    Peptides Oligonucleotides mAbs & Antibody Variants Antibody-drug Conjugates Recombinant Proteins Viral Vectors (AAV) Small Molecules & Nutraceuticals Impurity Isolation
    Contichrom® CUBE
    CUBE 30 (36 mL/min) CUBE 100 (100 mL/min) CUBE Software CUBE Accessories
    Contichrom® PILOT
    PILOT 300X (300 mL/min)
    Contichrom® TWIN HPLC
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Capture
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Polishing
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Demos & Introductions Training & Consulting System Rentals Process Modeling Feasibility Studies Custom Purification Maintenance & Repair
    By Application
    Peptides Oligonucleotides mAbs & Antibody Variants Antibody-drug Conjugates Recombinant Proteins Viral Vectors (AAV) Small Molecules & Nutraceuticals Impurity Isolation
    By System
    Contichrom® CUBE
    CUBE 30 (36 mL/min) CUBE 100 (100 mL/min) CUBE Software CUBE Accessories
    Contichrom® PILOT
    PILOT 300X (300 mL/min)
    Contichrom® TWIN HPLC
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Capture
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    Contichrom® TWIN LPLC - Polishing
    TWIN 300 (3.3 L/min) TWIN 500 (8.3 L/min) TWIN 1000 (18.9 L/min) TWIN 2000 (36 L/min)
    By Service
    Demos & Introductions Training & Consulting System Rentals Process Modeling Feasibility Studies Custom Purification Maintenance & Repair
  • Learning Center
    Technologies Resource Library Research Highlights Educational Articles
    Batch Chromatography Multi-Dimensional Chromatography (2D/3D) Continuous Capture (CaptureSMB®) Continuous Polishing (MCSGP) Continuous Enrichment (N-Rich®) Dynamic Process Control (AutoPeak® & AutomAb®)
    Application Notes Webinars & Videos Process Guides & Manuals Peer-Reviewed Publications Brochures & Datasheets White Papers
    Peptide Purification Oligonucleotide Purification
    Fundamentals of Preparative Chromatography Troubleshooting & Best Practices (Coming Soon)
    Technologies
    Batch Chromatography Multi-Dimensional Chromatography (2D/3D) Continuous Capture (CaptureSMB®) Continuous Polishing (MCSGP) Continuous Enrichment (N-Rich®) Dynamic Process Control (AutoPeak® & AutomAb®)
    Resource Library
    Application Notes Webinars & Videos Process Guides & Manuals Peer-Reviewed Publications Brochures & Datasheets White Papers
    Research Highlights
    Peptide Purification Oligonucleotide Purification
    Educational Articles
    Fundamentals of Preparative Chromatography Troubleshooting & Best Practices (Coming Soon)
  • About Us
    • About ChromaCon
    • News & Events
    • Distributors
    • Join our team
    • Contact
Get in Touch
English | Deutsch
Manage Consent

To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.

Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}